Skip to main content
Schneider Electric ENW24114

Schneider Electric ENW24114 EasyPact NW Circuit Breaker, 250

MPN ENW24114
Active

Schneider Electric EasyPact NW, ENW24114, 3-pole circuit breaker, 2500 A at 40 °C, 50 kA Icu at 440 V AC, fixed mount, rear connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24114 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24114 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24114 is a 3-pole EasyPact NW circuit breaker rated 2500 A at 40 °C, built for distribution duty in industrial switchboards. The Ics (service breaking capacity) matches the Icu at both voltage levels, so the breaker can reclose after a fault at full rating without derating. Mounting is fixed to a base plate with rear connections; the 115 mm connection pitch without spreader matches standard busbar layouts. IP40 enclosure protection keeps tools and fingers out but expects a panel door for washdown areas. The 25 ms maximum breaking time and 70 ms closing response give you the timing window for coordination with downstream breakers.

Designed and tested to IEC 60947-2 for circuit breakers. Rated impulse withstand voltage of 12 kV covers typical surge environments in industrial power distribution. Mechanical durability: 20,000 cycles with maintenance, 10,000 without — figures that inform your PM schedule.

MPN