Skip to main content
Schneider Electric ENW24114 — Air Circuit Breakers

Schneider Electric ENW24114 EasyPact NW Circuit Breaker, 250

MPNENW24114
Active

Schneider Electric EasyPact NW, ENW24114, 3-pole circuit breaker, 2500 A at 40 °C, 50 kA Icu at 440 V AC, fixed mount, rear connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24114 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24114 — Electrical ratings
ParameterValue
Rated current (In)2500 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24114 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24114 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24114 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width422 mm
Height352 mm
Depth297 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24114 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24114 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24114 is a 3-pole EasyPact NW circuit breaker rated 2500 A at 40 °C, built for distribution duty in industrial switchboards. The Ics (service breaking capacity) matches the Icu at both voltage levels, so the breaker can reclose after a fault at full rating without derating. Mounting is fixed to a base plate with rear connections; the 115 mm connection pitch without spreader matches standard busbar layouts. IP40 enclosure protection keeps tools and fingers out but expects a panel door for washdown areas. The 25 ms maximum breaking time and 70 ms closing response give you the timing window for coordination with downstream breakers.

Designed and tested to IEC 60947-2 for circuit breakers. Rated impulse withstand voltage of 12 kV covers typical surge environments in industrial power distribution. Mechanical durability: 20,000 cycles with maintenance, 10,000 without — figures that inform your PM schedule.

Frequently asked questions

Who supplies ENW24114 and how is it quoted for volume purchases?

The ENW24114 is sourced through independent distribution channels. Submit an RFQ for current pricing and lead time — availability is confirmed at quote time.

What is ENW24114's listed depth (297 mm) on this component line?

The ENW24114 has a depth of 297 mm, with a width of 422 mm and height of 352 mm. These dimensions fit standard switchgear cubicle depths.

What compliance documentation does this brand provide for ENW24114?

The ENW24114 is designed to IEC 60947-2 and carries a suitability-for-isolation declaration per that standard. It also meets pollution degree 4 per IEC 60664-1. For specific RoHS/REACH/UL declarations, request the manufacturer's compliance certificate with your RFQ.

MPN