Schneider Electric ENW24115 EasyPact NW Circuit Breaker, 320

MPN ENW24115
Active

Schneider Electric EasyPact NW, air circuit breaker, ENW24115, 3-pole, 3200 A at 40 °C, 50 kA Icu at 440 V AC, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24115 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24115 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

What the 3200 A and 50 kA ratings mean for your distribution board

The 42 kA Icu at 690 V AC covers higher-voltage installations. Both Icu and Ics (service breaking capacity) are identical at those voltages, so you get full rated breaking on every fault, not a derated service rating. The IP40 enclosure keeps out tools and wires larger than 1 mm, but it is not sealed against water; install it in a clean, dry panel.

Mechanical and electrical endurance — what to expect in service

Electrical durability (Category B) is 5,000 cycles at 440 V AC and 2,500 cycles at 690 V AC without maintenance, per IEC 60947-2. If your application cycles the breaker daily (e.g., generator paralleling or furnace switching), you will hit the maintenance interval faster than a breaker that operates a few times a year. Plan for contact inspection and lubrication at the 5,000-cycle mark. Maximum breaking time is 25 ms, and maximum closing response time is 70 ms — fast enough for most distribution networks, but if you need arc-flash mitigation with zone-selective interlocking, verify the trip unit coordination with your upstream relay settings.