Skip to main content
Schneider Electric ENW24116

Schneider Electric ENW24116 EasyPact NW Circuit Breaker, 400

MPN ENW24116
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24116, 4000 A at 40 °C, 55 kA Icu at 440 V AC, 3P, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24116 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity55 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24116 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24116 is an EasyPact NW air circuit breaker rated 4000 A at 40 °C, with a 55 kA Icu breaking capacity at 220…440 V AC 50/60 Hz per IEC 60947-2. Three-pole (3P), fixed-mount on a base plate, with rear vertical or horizontal connection. IP40 protection makes it suitable for indoor switchgear — clean, dry environments where dust ingress is minimal. The unit is Category B (selective) per IEC 60947-2, meaning it's designed for full discrimination with downstream breakers, so a fault on a feeder won't take the main bus down.

Rated service breaking capacity and withstand

Ics (service breaking capacity) matches Icu at 55 kA for 220…440 V AC and 42 kA at 690 V AC — that means after one fault interruption at those levels, the breaker is still rated to carry and switch its full load current. Short-time withstand (Icw) is 42 kA for 1 s at 690 V, 55 kA for 1 s at 440 V, and 30 kA for 3 s across the 440/690 V range. That 3-second rating is what lets you coordinate with downstream breakers for selective tripping: the main holds in for a delayed fault while the feeder clears.

MPN