Skip to main content
Schneider Electric ENW24118

Schneider Electric ENW24118 EasyPact NW Circuit Breaker, 100

MPN ENW24118
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24118, 1000 A at 40 °C, 50 kA Icu at 440 V AC, 4P, drawout, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24118 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24118 is a 4-pole EasyPact NW drawout circuit breaker rated 1000 A at 40 °C. That 1000 A continuous rating is the thermal current — sized for the main feeder or a large distribution bus, not a branch circuit. The 50 kA Icu at 220…440 V AC tells you it can safely interrupt a fault up to that level without failing; the 42 kA Icu at 690 V covers higher-voltage installations. IP40 keeps tools and fingers out but expects a panel enclosure for washdown areas.

Drawout integration and panel fit

Drawout mounting means the breaker slides into a cradle — no need to disconnect main cables for maintenance or swap. The rear connection and 115 mm connection pitch without spreader define the bus-bar or cable layout; vertical or horizontal connection positions give flexibility in the switchgear lineup. Rail mounting support and the 556 mm width, 439 mm height, 395 mm depth set the enclosure cutout and compartment size. Neutral position left matters if you're paralleling with an existing bus run.

Durability and electrical endurance

Category B utilisation means the breaker is designed for distribution duty with infrequent switching — not for motor starting. Electrical durability is 6000 cycles at 440 V and 4000 cycles at 690 V without maintenance. Mechanical durability is 20000 cycles with maintenance, 10000 without. Maximum breaking time is 25 ms, and maximum closing response time is 70 ms — fast enough for selective coordination in a tiered distribution system.

MPN
ENW24118