Schneider Electric EasyPact NW, circuit breaker, ENW24118, 1000 A at 40 °C, 50 kA Icu at 440 V AC, 4P, drawout, IP40.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24118 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24118 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24118 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24118 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24118 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRail
Contact position indicatorYes
Width556 mm
Height439 mm
Depth395 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24118 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24118 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24118 is a 4-pole EasyPact NW drawout circuit breaker rated 1000 A at 40 °C. That 1000 A continuous rating is the thermal current — sized for the main feeder or a large distribution bus, not a branch circuit. The 50 kA Icu at 220…440 V AC tells you it can safely interrupt a fault up to that level without failing; the 42 kA Icu at 690 V covers higher-voltage installations. IP40 keeps tools and fingers out but expects a panel enclosure for washdown areas.

Drawout integration and panel fit

Drawout mounting means the breaker slides into a cradle — no need to disconnect main cables for maintenance or swap. The rear connection and 115 mm connection pitch without spreader define the bus-bar or cable layout; vertical or horizontal connection positions give flexibility in the switchgear lineup. Rail mounting support and the 556 mm width, 439 mm height, 395 mm depth set the enclosure cutout and compartment size. Neutral position left matters if you're paralleling with an existing bus run.

Durability and electrical endurance

Category B utilisation means the breaker is designed for distribution duty with infrequent switching — not for motor starting. Electrical durability is 6000 cycles at 440 V and 4000 cycles at 690 V without maintenance. Mechanical durability is 20000 cycles with maintenance, 10000 without. Maximum breaking time is 25 ms, and maximum closing response time is 70 ms — fast enough for selective coordination in a tiered distribution system.

Frequently asked questions

What is the breaking capacity of ENW24118?

50 kA Icu at 220…440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) matches those values.