Schneider Electric ENW24126 — Air Circuit Breakers

Schneider Electric ENW24126 EasyPact NW Circuit Breaker, 100

MPNENW24126
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24126, 4P, 1000 A at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2, IP40, fixed mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24126 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24126 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24126 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24126 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24126 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24126 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24126 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric ENW24126 is a 4-pole EasyPact NW air circuit breaker rated 1000 A at 40 °C — the continuous current it can carry without derating in a typical 40 °C panel environment. That 1000 A figure is the thermal rating (In), not a short-time or instantaneous pickup; it governs the main bus or feeder it protects. Breaking capacity is 50 kA Icu at 220…440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2. The Icu (ultimate breaking capacity) means the breaker can safely interrupt one fault at that level and still be functional afterward — it does not guarantee further service without inspection. Rated operational voltage (Ue) is 690 V AC, and rated insulation voltage (Ui) is 1000 V AC — the latter tells you the internal creepage and clearance are designed for a 1000 V system, even though the breaker is applied at 690 V. That headroom matters for installations where the system voltage may rise or where the breaker sits in a higher-voltage switchgear lineup.

Deployment context and physical integration

This is a fixed-mount breaker on a base plate, not a draw-out or plug-in unit. Dimensions are 537 mm wide × 352 mm high × 297 mm deep — a substantial footprint that needs a dedicated compartment in the switchgear lineup, not a DIN-rail clip. That means it can serve as a disconnecting means for a feeder, satisfying the lockout/tagout requirement without a separate disconnect switch.

Designed and tested to IEC 60947-2, the international standard for low-voltage circuit breakers. This covers the breaking capacity ratings, service duty, and isolation suitability listed above. The pollution degree 4 rating per IEC 60664-1 is an additional environmental classification that goes beyond the base standard.

Frequently asked questions

What is ENW24126's breaking capacity at 440 V?

50 kA Icu and 50 kA Ics at 220…440 V AC, 50/60 Hz, per IEC 60947-2. At 690 V the rating is 42 kA Icu and 42 kA Ics.