Schneider Electric ENW24129

Schneider Electric ENW24129 EasyPact NW Circuit Breaker, 200

MPN ENW24129
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24129, 2000 A at 40 °C, 4P, 50 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24129 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24129 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

What this 2000 A EasyPact NW breaker is for

It carries a 50 kA Icu at 220–440 V AC and 42 kA Icu at 690 V AC per IEC 60947-2, so it handles high-fault utility feeds without cascading upstream. The 1000 V rated insulation voltage (Ui) and 690 V operational voltage (Ue) cover standard 400/480 V and 690 V plant networks.

The ENW24129's breaking capacity code is N, with a symmetrical Icu of 50 kA at 440 V and 42 kA at 690 V. The Ics (service breaking capacity) matches those same figures, so the breaker can reclose after a fault at full rated voltage without derating — important for selectivity studies in a distribution board. Maximum breaking time is 25 ms, and maximum closing response time is 70 ms, giving a fast enough clearing for downstream coordination with MCCBs and fuses. Category B utilisation means it's designed for distribution with no intentional short-time delay; if you need selectivity with a deliberate delay, verify the trip unit settings against the downstream devices.

Fixed-mount base plate installation, rear vertical or horizontal connection positions. The 115 mm connection pitch without spreader matches standard busbar riser spacing in LV switchgear. Neutral position is left, and the 4-pole protected poles description is 4P 4d — all four poles are protected. Dimensions: 537 mm wide × 352 mm high × 297 mm deep.