Skip to main content
Schneider Electric ENW24136

Schneider Electric ENW24136 EasyPact NW Circuit Breaker, 160

MPN ENW24136
Active

Schneider Electric EasyPact NW, air circuit breaker, ENW24136, 1600 A at 40 °C, 66 kA Icu at 440 V AC, 3-pole drawout, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24136 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24136 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24136 is a 1600 A air circuit breaker from the EasyPact NW range, built for distribution duty in industrial switchboards. It is a 3-pole drawout unit — meaning the breaker body slides out of its cradle for safe inspection or swap without disturbing the bus connections. Rated operational voltage is 690 V AC, with a breaking capacity of 66 kA Icu at 440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. That puts it in the H (high) breaking capacity class for this frame size. The IP40 enclosure keeps tools and fingers out but is not washdown-rated.

For a 1600 A bus or a large transformer secondary, this is the right frame size. Short-time withstand (Icw) is 65 kA for 1 second at 440 V and 36 kA for 3 seconds at 440/690 V. That delay lets downstream breakers clear a fault first — essential for selective coordination in a distribution panel. Utilisation category B confirms the breaker is designed for this selective operation with intentional short delay. Electrical durability is 6,000 cycles at 440 V without maintenance. For a main breaker that operates infrequently (a few times a year for switching), this is more than adequate. For a machine-tool disconnect cycled daily, it is not the right choice — look at a contactor-based solution instead.

Push-button control on the front panel for open/close operations. Contact position indicator gives visual confirmation of the main contact state — no need to open the door to verify.

Compliance documentation includes IEC 60947-2 certification. For specific RoHS, REACH, or UL documentation requests, include them with the RFQ so the compliance package can be attached to the quote.

MPN
ENW24136