Schneider Electric ENW24137 EasyPact NW Circuit Breaker, 200

MPNENW24137
Active

Schneider Electric EasyPact NW, ENW24137, 3P drawout air circuit breaker, 2000 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24137 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24137 — Electrical ratings
ParameterValue
Rated current (In)2000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24137 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24137 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24137 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRail
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24137 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24137 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

What this 2000 A drawout breaker does on your line

It's built for main distribution duty in industrial switchgear — the kind of breaker that sits between a transformer secondary and a plant's main bus, not a feeder branch. The 66 kA Icu at 440 V AC (50/60 Hz) means it can interrupt a fault current up to that level without failing, and the 50 kA Icu at 690 V AC covers higher-voltage installations. That's Category B utilisation (IEC 60947-2), so it's fully rated for selectivity with downstream breakers — you can coordinate trips so only the faulted section clears, keeping the rest of the plant live. Pollution degree 4 per IEC 60664-1 is the heavy-duty rating — it's designed for conductive dust, condensation, or industrial atmospheres where a standard breaker's creepage distances might track. The 12 kV impulse withstand voltage (Uimp) backs that up for surge environments like large motor starts or nearby lightning.

Durability and service intervals

Mechanical durability is 20,000 cycles with maintenance and 10,000 without per IEC 60947-2 — that's a long service life for a main breaker that might operate a few times a year. Electrical durability is 6,000 cycles at 440 V and 4,000 at 690 V without maintenance. The 25 ms maximum breaking time is fast enough for most coordination schemes. IP40 protection means it's splash-proof against tools and fingers but not water — keep it indoors or in a weatherproof enclosure.

Frequently asked questions

How do I get current pricing and availability for the ENW24137?

The ENW24137 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What are the key ratings for the ENW24137?

Rated current is 2000 A at 40 °C. Breaking capacity is 66 kA Icu at 220-440 V AC and 50 kA Icu at 690 V AC. Rated operational voltage is 690 V AC, insulation voltage is 1000 V AC, and impulse withstand voltage is 12 kV. All per IEC 60947-2.

What is the ENW24137's depth?

The ENW24137 has a listed depth of 395 mm for the drawout cassette. Overall dimensions are 441 mm width by 439 mm height.

What compliance documentation does Schneider provide for the ENW24137?

The ENW24137 is designed and tested to IEC 60947-2 for circuit breakers. It carries a suitability-for-isolation marking per that standard. For specific compliance documentation (RoHS, REACH, UL listing), request the manufacturer's declaration with your RFQ.

MPN
ENW24137