Skip to main content
Schneider Electric ENW24140

Schneider Electric ENW24140 EasyPact NW Circuit Breaker, 400

MPN ENW24140
Active

Schneider Electric EasyPact NW series, ENW24140 air circuit breaker, 3-pole, 4000 A at 40 °C, 66 kA Icu at 440 V AC, drawout mounting, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24140 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24140 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24140 is a 3-pole air circuit breaker from the EasyPact NW range, rated 4000 A at 40 °C with a breaking capacity of 66 kA Icu at 440 V AC per IEC 60947-2. Drawout mounting lets you rack the breaker out for maintenance without disturbing the busbars, which is standard for switchgear that needs periodic inspection or swap-out.

Deployment context

This breaker is designed for drawout mounting on a rail, which places it in metal-enclosed low-voltage switchgear assemblies — think main incomers or large feeder breakers in industrial distribution panels. Pollution degree 4 per IEC 60664-1 confirms it's rated for harsh conductive environments (heavy dust, condensation), which is typical for heavy industrial settings like steel mills or cement plants.

Rated insulation voltage 1000 V AC and impulse withstand voltage 12 kV mean the breaker's internal clearances are designed for 1 kV systems, so it can be used on 690 V networks with ample margin. Utilisation category B means it's intended for distribution duty with no frequent switching of motor starts; the electrical durability is 5000 cycles at 440 V without maintenance, which is typical for a breaker that stays closed most of its life.

MPN
ENW24140