Skip to main content
Schneider Electric ENW24141

Schneider Electric ENW24141 EasyPact NW Circuit Breaker, 800

MPN ENW24141
Active

Schneider Electric EasyPact NW, ENW24141, air circuit breaker, 3P, 800 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2, IP40, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24141 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24141 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

What this 800 A EasyPact NW breaker is for

It's a fixed-mount, 3-pole unit with a push-button control type, designed for vertical or horizontal rear connection at a 115 mm pitch without spreader. The H breaking capacity code means 66 kA Icu at 220...440 V AC 50/60 Hz and 50 kA Icu at 690 V AC 50/60 Hz — enough headroom for most low-voltage distribution faults without cascading upstream.

That's a strong selectivity story for a main or tie breaker in a distribution board. The rated short-time withstand current Icw is 65 kA for 1 s at 440 V, so it coordinates with downstream devices during a delayed trip. Rated insulation voltage Ui is 1000 V AC, and impulse withstand Uimp is 12 kV — both confirm the clearance and creepage distances for a 690 V system with pollution degree 4 (heavy industrial environment per IEC 60664-1).

Integration into a switchboard

Fixed-mount on a base plate, with rear vertical or horizontal connection at 115 mm pitch. The 422 mm width by 352 mm height by 297 mm depth footprint fits standard low-voltage switchgear cubicles. IP40 protection means it's suited for indoor panel installation — not washdown environments. Mechanical durability is 20,000 cycles with maintenance, 10,000 without; electrical durability is 6,000 cycles at 440 V AC, 4,000 at 690 V AC, both Category B without maintenance per IEC 60947-2.

MPN
ENW24141