Skip to main content
Schneider Electric ENW24156

Schneider Electric ENW24156 EasyPact NW Circuit Breaker, 400

MPN ENW24156
Active

Schneider Electric EasyPact NW, ENW24156, 4-pole drawout circuit breaker, 4000 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24156 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24156 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24156 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 4000 A at 40 °C with a breaking capacity of 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, per IEC 60947-2. It's a Category B breaker — meaning it's designed for distribution in industrial switchgear where selectivity and coordination with downstream devices matter. The drawout mounting lets you rack the breaker out for maintenance without disturbing the bus connections, which is standard for large low-voltage mains and tie feeders.

At 690 V the Icu drops to 50 kA, which still covers most industrial 690 V distribution. The 25 ms maximum break time is fast enough to limit let-through energy for downstream coordination.

Integration notes

Mounts on a rail with drawout mechanism — rear horizontal or vertical connection positions, 115 mm connection pitch without spreader. IP40 enclosure protection; suitable for indoor switchgear cubicles. Control is push-button operated. Ambient operating range -5 to 60 °C; storage down to -40 °C without control unit. Mechanical durability: 20,000 cycles with maintenance, 10,000 without.

MPN
ENW24156