Skip to main content
Schneider Electric ENW24160 — Air Circuit Breakers

Schneider Electric ENW24160 EasyPact NW Circuit Breaker, 160

MPNENW24160
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24160, 1600 A at 40 °C, 66 kA Icu at 440 V AC, 4P, IP40, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24160 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24160 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24160 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24160 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24160 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24160 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24160 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric ENW24160 is a 4-pole EasyPact NW circuit breaker rated for 1600 A at 40 °C, with a breaking capacity of 66 kA Icu at 220–440 V AC and 50 kA Icu at 690 V AC per IEC 60947-2.

The 1600 A rated current (In) at 40 °C sets the continuous load it can carry in a typical 40 °C enclosure ambient. If your panel runs hotter, you'll need to derate — the IEC 60947-2 standard governs that curve. At 690 V the Icu drops to 50 kA, so verify your system voltage against that ceiling. The IP40 enclosure keeps out tools and debris larger than 1 mm but is not washdown-rated; mount it inside a panel or enclosure for wet-area duty.

Fixed mounting on a base plate, rear connection with a 115 mm pitch without spreader. The 537 mm width, 352 mm height, and 297 mm depth mean it needs a substantial cutout in the panel floor — plan for a dedicated compartment, not a shared DIN-rail section. Neutral position is left; the 4P 4d configuration protects all poles including the neutral. Push-button control with a contact position indicator gives local status without opening the door.

Frequently asked questions

Where can I buy ENW24160 and get current pricing?

The ENW24160 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of ENW24160 at 440 V?

The ENW24160 has a breaking capacity of 66 kA Icu at 220–440 V AC and 65 kA Ics at the same voltage per IEC 60947-2.

What standards does ENW24160 comply with?

The ENW24160 complies with IEC 60947-2 for circuit breakers and IEC 60664-1 for pollution degree 4 insulation coordination.

MPN