Schneider Electric ENW24161 EasyPact NW Circuit Breaker, 200

MPN ENW24161
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24161, 2000 A at 40 °C, 66 kA Icu at 440 V AC, 4P, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24161 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24161 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24161 is a 4-pole EasyPact NW air circuit breaker rated 2000 A at 40 °C, with a breaking capacity of 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC per IEC 60947-2. The 50 kA at 690 V covers industrial 690 V distribution, though the Ics (service breaking capacity) matches the Icu at each voltage level, so it can reclose after a fault without derating. The IP40 enclosure keeps tools and fingers out but is not washdown-rated; mount in a cabinet for wet areas.

Deployment context

Fixed-mount base-plate installation with rear vertical or horizontal connections. The 115 mm connection pitch without spreader matches standard busbar layouts for 2000 A switchgear. Neutral position left, 4P 4d protected poles — covers full four-wire distribution with neutral protection configurable to 0.5 x Ir or 1 x Ir. Mechanical durability of 20,000 cycles with maintenance, 10,000 without; electrical durability of 6,000 cycles at 440 V and 4,000 at 690 V without maintenance — adequate for infrequent switching in distribution, not for frequent motor starting.

Certified to IEC 60947-2, with suitability for isolation marked on the device. The contact position indicator gives visual confirmation of open/closed state — a survey requirement for isolation duty. The breaker's 25 ms maximum breaking time and 70 ms maximum closing response time are typical for air power breakers in this class.