Schneider Electric ENW24162 — Air Circuit Breakers

ENW24162 EasyPact NW Circuit Breaker, 2500 A, 66 kA

MPNENW24162
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24162, 2500 A at 40 °C, 66 kA Icu at 440 V AC, 4P, fixed mount, rear connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24162 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24162 — Electrical ratings
ParameterValue
Rated current (In)2500 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24162 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24162 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24162 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24162 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24162 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24162 is a 2500 A fixed-mount air circuit breaker from the EasyPact NW range, built for distribution duty in industrial switchboards. For a 690 V system the Icu drops to 50 kA, still enough for most industrial networks.

Deployment context

This is a fixed-mount breaker — no draw-out cradle. It bolts to a base plate in the switchgear cubicle, with rear horizontal or vertical bus connections. The 537 mm width, 352 mm height, and 297 mm depth define the cubicle cell it fits into. Connection pitch is 115 mm without a spreader. The IP40 enclosure keeps out tools and small debris but is not sealed against water — install in a dry indoor switchroom.

The breaker is designed to IEC 60947-2 for low-voltage switchgear and controlgear.

Mechanical endurance is 20,000 cycles with maintenance, 10,000 without. Electrical endurance at 440 V is 5,000 cycles Category B; at 690 V it drops to 2,500 cycles. Maximum breaking time is 25 ms, closing response time 70 ms. For a main breaker that operates a few times a year, these numbers are generous; for a frequent-switching application like a welding bus, the electrical endurance at 690 V becomes the limiting factor.

Neutral configuration

The 4P breaker with protected poles (4d) allows several neutral protection settings: no protection (3D), 0.5 x Ir (3D + N/2), or 1 x Ir (4D). This flexibility matters when the neutral conductor is undersized relative to the phases or when the system requires full neutral protection.

Frequently asked questions

Where can I buy ENW24162?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of ENW24162?

Rated current 2500 A at 40 °C, breaking capacity 66 kA Icu at 440 V AC and 50 kA at 690 V AC, rated insulation voltage 1000 V AC, all per IEC 60947-2.

What is the closest alternative to ENW24162?

Within the EasyPact NW range, the closest sibling is the draw-out version (ENW24162 is fixed-mount). The fixed-mount frame and ratings are the same; the draw-out variant adds a cradle for racking in and out. No pin-compatible alternative exists outside the family — the 2500 A frame and rear-connection pattern are specific to this order code.

What compliance documentation does Schneider provide for ENW24162?

The breaker is designed to IEC 60947-2 and IEC 60664-1 (pollution degree 4). Standard Schneider documentation includes a declaration of conformity and the IEC test certificate. RoHS and REACH compliance are covered by the manufacturer's general material declarations for the EasyPact NW range.

MPN
ENW24162