Skip to main content
Schneider Electric ENW24176

ENW24176 EasyPact NW Switch Disconnector, 1600 A, 3P

MPN ENW24176
Active

Schneider Electric EasyPact NW, switch disconnector, ENW24176, 1600 A AC-23A, 3 poles, fixed mount, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24176 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage690 V AC 50/60 Hz conforming to IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-3
CurrentAC-23 A: 1600 A AC 50/60 Hz 690 V
Utilization categoryAC-23 A
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C

All specifications

ENW24176 additional specifications
ParameterValue
Storage temperature-40...85 °C without control unit
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3
ApplicationDistribution
Operating temperature-5...70 °C

Product details

Switch disconnector for distribution, 1600 A, AC-23A

The Schneider Electric ENW24176 is a fixed-mount switch disconnector from the EasyPact NW range, rated 1600 A in AC-23A duty at 690 V AC. That AC-23A utilisation category means it handles switching of motors and other highly inductive loads — not just resistive break — so it's suited for distribution panels feeding motor control centres or large transformer loads.

Withstand and making capacity

Rated short-time withstand current (Icw) is 50 kA for 1 s or 25 kA for 3 s at the full operating temperature range (-5 to 70 °C). That gives protection coordination engineers a solid window for upstream breaker clearing times. The rated short-circuit making capacity (Icm) is 105 kA at 50/60 Hz — meaning it can close onto a fault without welding contacts, which matters when you're restoring power after a trip.

Physical integration and environment

Footprint is 422 mm wide by 352 mm high by 297 mm deep — a substantial unit that bolts to a base plate (fixed mounting, not DIN rail). Connection is rear-entry, horizontal or vertical orientation, with a 115 mm pitch without spreader.

MPN
ENW24176