Skip to main content
Schneider Electric ENW24202

Schneider Electric ENW24202 EasyPact NW Switch Disconnector,

MPN ENW24202
Active

Schneider Electric EasyPact NW switch disconnector, ENW24202, 2500 A AC-23A, 3 poles, drawout, H breaking capacity, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24202 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage690 V AC 50/60 Hz conforming to IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-3
CurrentAC-23 A: 2500 A AC 50/60 Hz 690 V
Utilization categoryAC-23 A
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C

All specifications

ENW24202 additional specifications
ParameterValue
Storage temperature-40...85 °C without control unit
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3
ApplicationDistribution
Operating temperature-5...70 °C

Product details

What the 2500 A AC-23A rating means for your line

The ENW24202 is a 3-pole switch disconnector from the EasyPact NW range, rated 2500 A in utilisation category AC-23A at 690 V AC. AC-23A covers switching of mixed resistive and inductive loads including motor loads — so this part handles frequent on-load switching of motors, transformers, and capacitor banks, not just isolation. The 2500 A figure is the operational current under that duty; it is not a no-load rating. Rated short-time withstand current is 66 kA for 1 s (36 kA for 3 s) per IEC 60947-3, and the short-circuit making capacity reaches 143 kA peak. That means the switch can close onto a fault and hold the thermal/mechanical stress until an upstream breaker clears — critical for selectivity in a distribution panel.

Drawout mounting and panel integration

Drawout mounting (withdrawal type) means the switch chassis slides out of its cradle for inspection or replacement without disturbing the main bus connections. Rear connection, vertical or horizontal orientation. The 115 mm connection pitch without spreader matches standard busbar spacing in LV switchgear.

Standards compliance includes IEC 60947-3 for switch-disconnectors, with suitability for isolation marked on the nameplate. The contact position indicator gives visual confirmation of open/closed state — no need to verify with a meter before racking out.

MPN
ENW24202