Skip to main content
Schneider Electric ENW24211

Schneider Electric ENW24211 EasyPact NW Switch Disconnector,

MPN ENW24211
Active

Schneider Electric EasyPact NW, switch disconnector, ENW24211, 3200 A AC-23A, 3 poles, fixed mounting, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24211 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage690 V AC 50/60 Hz conforming to IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-3
CurrentAC-23 A: 3200 A AC 50/60 Hz 690 V
Utilization categoryAC-23 A
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C

All specifications

ENW24211 additional specifications
ParameterValue
Storage temperature-40...85 °C without control unit
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3
ApplicationDistribution
Operating temperature-5...70 °C

Product details

Switch disconnector for high-current distribution

The Schneider Electric ENW24211 is a fixed-mount switch disconnector from the EasyPact NW range, rated for 3200 A in AC-23A duty at 690 V AC. That AC-23A utilisation category covers switching of motor loads and other highly inductive circuits — it is not a general-purpose load-break switch; the 3200 A figure applies specifically to motor switching, not resistive heating. Rated insulation voltage is 1000 V AC, with an impulse withstand of 12 kV per IEC 60947-3. Short-time withstand current is 66 kA for 1 s and 36 kA for 3 s, giving selectivity headroom for downstream breakers in a distribution board. The making capacity (Icm) is 143 kA peak, which covers the worst-case asymmetrical fault current on a 50/60 Hz system.

Fixed mounting on a base plate; rear connection with a horizontal or vertical orientation. The 422 mm width × 352 mm height × 297 mm depth footprint fits into standard low-voltage switchgear cubicles. Connection pitch is 115 mm without spreader — verify busbar drilling pattern against that dimension.

MPN
ENW24211