Schneider Electric ENW24232

Schneider Electric ENW24232 EasyPact NW Circuit Breaker, 160

MPN ENW24232
Active

Schneider Electric EasyPact NW, ENW24232, 4-pole drawout circuit breaker, 1600 A at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24232 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24232 is a 4-pole drawout circuit breaker from Schneider Electric's EasyPact NW range, rated 1600 A at 40 °C and built for distribution duty per IEC 60947-2. The drawout cradle lets you rack the breaker out for maintenance or replacement without disturbing the bus connections, which saves hours on a line shutdown.

The 50 kA Icu at 440 V AC is the ultimate breaking capacity — the breaker can clear one fault at that level and still be functional afterward. The Ics (service breaking capacity) is the same 50 kA at 440 V, meaning it can clear multiple faults at that rating and remain in service, which is unusual at this current level. At 690 V the Icu drops to 42 kA, still a strong figure for a 1600 A frame. The Icw short-time withstand is 50 kA for 1 second at 440 V, which gives you the thermal margin for delayed tripping in selective coordination — you can let a downstream breaker clear first without the main tripping prematurely.

Mounting and integration — drawout cradle on rails, rear connection

Mounts on a rail via the drawout cradle — the breaker racks in and out, so you can isolate it without unbolting bus bars. Connection pitch is 115 mm without a spreader, and the rear connection position suits fixed-panel buswork. The IP40 enclosure keeps dust out but is not rated for washdown; install in a clean indoor switchgear lineup.

Electrical endurance and duty cycle

Electrical durability at 440 V is 6,000 cycles without maintenance — enough for daily switching in a distribution feeder. Maximum breaking time is 25 ms, closing response 70 ms, so it clears faults fast enough to limit arc-flash energy in a properly coordinated system.

MPN
ENW24232