Schneider Electric ENW24240 EasyPact NW Circuit Breaker, 160

MPNENW24240
Active

Schneider Electric EasyPact NW, air circuit breaker, ENW24240, 1600 A at 40 °C, 4 poles, 50 kA Icu at 440 V AC, fixed mounting, IP40.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24240 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24240 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24240 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24240 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24240 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionRight
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24240 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24240 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24240 is a 1600 A air circuit breaker from the EasyPact NW range, built for main distribution boards and large industrial feeders. At 690 V AC the Icu drops to 42 kA, which still covers most 690 V motor-control centers. The Ics (service breaking capacity) matches the Icu at both voltage levels, so you can reclose after a fault at full rating without derating the breaker — that's Category B utilization, meaning it's designed for sustained service in high-fault environments, not just backup protection. The 1600 A continuous rating is at 40 °C ambient. If your switchroom runs hotter — say 50 °C — you'll need to derate per the manufacturer's curve, which is standard for any air breaker this size.

Fixed mounting on a base plate — no draw-out cradle. That saves panel depth but means the breaker must be isolated upstream before any maintenance. Rear connection, vertical or horizontal orientation, with a connection pitch of 115 mm without spreader. The neutral is on the right (4-pole configuration). Dimensions: 537 mm wide, 352 mm high, 297 mm deep. IP40 enclosure protection — fine for indoor switchgear, but not for washdown areas. The push-button control on the front cover gives local open/close/reset without opening the door.

Mechanical durability: 20,000 cycles with maintenance, 10,000 without. Electrical durability: 6,000 cycles at 440 V AC without maintenance, 4,000 at 690 V. That's typical for a Category B air breaker — it's meant for switching under load, not just as a disconnect. The maximum breaking time is 25 ms, closing response 70 ms, so it clears faults fast enough for most coordination studies. The short-time withstand current (Icw) is 50 kA for 1 second at 440 V, 42 kA at 690 V, and 25 kA for 3 seconds at both voltages — that's the rating that matters for selective coordination with downstream breakers, because it tells you how long the breaker can carry a fault current without tripping while the downstream device clears.

Frequently asked questions

What is ENW24240's breaking capacity at 440 V?

50 kA Icu (ultimate breaking capacity) at 220...440 V AC 50/60 Hz per IEC 60947-2. The Ics (service breaking capacity) is the same 50 kA at that voltage range.

What is the closest alternative to ENW24240 in the EasyPact NW family?

Within the same EasyPact NW range, the draw-out version (order code differs) shares the same 1600 A frame and breaking capacities but mounts in a cradle with racking mechanism. The fixed-mount ENW24240 is the simpler, lower-cost option for panels where draw-out isn't required.

Where can I buy ENW24240 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
ENW24240