Skip to main content
Schneider Electric ENW24242 — Air Circuit Breakers

Schneider Electric ENW24242 EasyPact NW Circuit Breaker, 250

MPNENW24242
Active

Schneider Electric EasyPact NW, ENW24242, air circuit breaker, 2500 A at 40 °C, 4P, 50 kA Icu at 440 V AC, IEC 60947-2, fixed mounting, IP40.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24242 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24242 — Electrical ratings
ParameterValue
Rated current (In)2500 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24242 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24242 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24242 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionRight
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24242 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24242 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric ENW24242 is a 4-pole EasyPact NW air circuit breaker rated at 2500 A continuous at 40 °C ambient — that is the full-load current it carries without derating in a typical switchroom environment. The 50 kA Icu at 440 V AC (per IEC 60947-2) tells you the maximum fault current it can interrupt once and remain functional; the service breaking capacity Ics is the same 50 kA at that voltage, meaning it can clear a fault and be reclosed without immediate replacement — a critical distinction for selectivity studies and maintenance planning. Rated insulation voltage Ui is 1000 V AC, and rated impulse withstand Uimp is 12 kV — these govern the creepage and clearance distances inside the breaker. With pollution degree 4 per IEC 60664-1, the ENW24242 is designed for harsh industrial atmospheres where conductive dust or condensation is present; the IP40 enclosure keeps tools and fingers out but is not sealed against water ingress. The short-time withstand current Icw is 50 kA for 1 second at 440 V, which supports delayed tripping for downstream selectivity coordination — you can set the trip curve so a feeder breaker clears a fault before this main breaker opens, keeping the rest of the bus live.

Integration into the switchboard

Fixed mounting on a base plate — no draw-out cradle. The rear connection pitch is 115 mm without spreader, horizontal or vertical orientation. Dimensions are 537 mm wide by 352 mm high by 297 mm deep; verify the compartment depth in your switchboard before committing, as the 297 mm projection plus cable bending radius drives the enclosure depth. Push-button control on the front panel. The neutral is on the right-hand pole position.

Mechanical endurance is 20,000 cycles with maintenance, 10,000 without. Electrical endurance at 440 V AC is 5,000 cycles without maintenance under Category B duty (the breaker is designed for distribution, not frequent motor switching). Maximum breaking time is 25 ms; maximum closing response time is 70 ms.

Frequently asked questions

Where can I buy the ENW24242 and get a price?

The ENW24242 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the breaking capacity of the ENW24242 at 440 V?

The ultimate breaking capacity Icu is 50 kA at 220...440 V AC, and the service breaking capacity Ics is the same 50 kA at that voltage. At 690 V AC both ratings drop to 42 kA.

What standards does the ENW24242 comply with?

It complies with IEC 60947-2 for circuit breakers. Pollution degree 4 per IEC 60664-1. Suitability for isolation is confirmed per IEC 60947-2.

MPN
ENW24242