Schneider Electric ENW24248 EasyPact NW Circuit Breaker, 160

MPN ENW24248
Active

Schneider Electric EasyPact NW, ENW24248, 4-pole drawout circuit breaker, 1600 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24248 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24248 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24248 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 1600 A at 40 °C with a 66 kA Icu breaking capacity at 220...440 V AC 50/60 Hz per IEC 60947-2. The 65 kA Ics (service breaking capacity) at the same voltage tells you it can clear a fault and be immediately returned to service without inspection, which matters for uptime in continuous-process plants.

The 12 kV impulse withstand (Uimp) confirms it handles switching surges and lightning-induced transients on exposed feeders. Pollution degree 4 per IEC 60664-1 means the creepage distances are sized for conductive dust or condensation — think cement plants or unheated switchrooms, not just clean data centers.

Drawout mounting and panel integration

Drawout mounting means the breaker chassis stays wired to the bus, and the moving portion racks out for maintenance or swap without disturbing the primary connections. Rear vertical/horizontal connection positions give flexibility for cable entry direction in the switchgear lineup. The 115 mm connection pitch without spreader is the dimension to check against your existing bus bar centers — if you're retrofitting into an older board, measure first. IP40 protection is fine for indoor switchgear; no washdown rating here, so keep it out of the hose-down zone.