Skip to main content
Schneider Electric ENW24254 — Air Circuit Breakers

Schneider Electric ENW24254 EasyPact NW Circuit Breaker, 100

MPNENW24254
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24254, 1000 A at 40 °C, 66 kA Icu at 440 V AC, 4P, fixed mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24254 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24254 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24254 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24254 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24254 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionRight
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24254 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24254 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric ENW24254 is a 4-pole EasyPact NW air circuit breaker rated for 1000 A at 40 °C, built to IEC 60947-2. The 65 kA service breaking capacity (Ics) at the same voltage tells you it can clear a fault and still be reclosed without maintenance, which is what you want for a main breaker in a continuous-process plant where a nuisance trip can't mean a half-day swap. The short-time withstand rating (Icw) of 65 kA for 1 second at 440 V supports selectivity coordination downstream.

The push-button control on the front gives you local open/close without reaching for a separate switch. Neutral position is on the right, which matters when you're laying out busbars in a common enclosure.

Durability and maintenance cycles

Mechanical durability is 20,000 cycles with maintenance, 10,000 without — that's a lot of operations for a 1000 A frame, so it's fine for switching a capacitor bank or a large motor infrequently. Electrical durability is 6,000 cycles at 440 V AC without maintenance per IEC 60947-2, dropping to 4,000 cycles at 690 V AC. The 25 ms maximum breaking time is fast enough to limit arc energy in a bolted fault.

Frequently asked questions

What is ENW24254's breaking capacity at 440 V?

The ultimate breaking capacity (Icu) is 66 kA at 220...440 V AC, and the service breaking capacity (Ics) is 65 kA at the same voltage, both per IEC 60947-2.

What standards does ENW24254 comply with?

It is designed and tested to IEC 60947-2, and the insulation coordination meets pollution degree 4 per IEC 60664-1.

MPN