Schneider Electric ENW24254 EasyPact NW Circuit Breaker, 100

MPN ENW24254
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24254, 1000 A at 40 °C, 66 kA Icu at 440 V AC, 4P, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24254 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24254 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The Schneider Electric ENW24254 is a 4-pole EasyPact NW air circuit breaker rated for 1000 A at 40 °C, built to IEC 60947-2. The 65 kA service breaking capacity (Ics) at the same voltage tells you it can clear a fault and still be reclosed without maintenance, which is what you want for a main breaker in a continuous-process plant where a nuisance trip can't mean a half-day swap. The short-time withstand rating (Icw) of 65 kA for 1 second at 440 V supports selectivity coordination downstream.

The push-button control on the front gives you local open/close without reaching for a separate switch. Neutral position is on the right, which matters when you're laying out busbars in a common enclosure.

Durability and maintenance cycles

Mechanical durability is 20,000 cycles with maintenance, 10,000 without — that's a lot of operations for a 1000 A frame, so it's fine for switching a capacitor bank or a large motor infrequently. Electrical durability is 6,000 cycles at 440 V AC without maintenance per IEC 60947-2, dropping to 4,000 cycles at 690 V AC. The 25 ms maximum breaking time is fast enough to limit arc energy in a bolted fault.

MPN