Specifications

ENW24264 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage690 V AC 50/60 Hz conforming to IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-3
CurrentAC-23 A: 1600 A AC 50/60 Hz 690 V
Utilization categoryAC-23 A
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C

All specifications

ENW24264 additional specifications
ParameterValue
Storage temperature-40...85 °C without control unit
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
Mechanical life cycles20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3
ApplicationDistribution
Operating temperature-5...70 °C

Product details

Switch disconnector, 1600 A, drawout — EasyPact NW

The Schneider Electric ENW24264 is a 4-pole switch disconnector from the EasyPact NW range, rated 1600 A in AC-23A utilization category at 690 V AC. Drawout mounting lets the chassis slide out of the cradle for maintenance without disturbing the power wiring — a standard arrangement for switchgear where the disconnect needs to be racked out for safe access. The rear connection with a 115 mm pitch without spreader matches common busbar or cable-box layouts in low-voltage switchboards.

Rated short-time withstand current (Icw) is 50 kA for 1 s or 25 kA for 3 s. That tells you the switch can carry fault current for that duration without welding or damage, which is the key figure for downstream coordination with a circuit breaker or fuse — the upstream protective device must clear within those limits. The rated short-circuit making capacity (Icm) of 105 kA AC means it can close onto an existing fault and survive; this matters when the switch is used as a main disconnect that may be closed onto a bolted fault downstream. Pollution degree 4 per IEC 60664-1 is the highest severity — conductive dust or condensation is expected, so the creepage distances are designed for harsh industrial environments.

MPN