Skip to main content
Schneider Electric ENW24272 — Air Circuit Breakers

ENW24272 EasyPact NW Switch Disconnector, 1600A, 4P

MPNENW24272
Active

Schneider Electric EasyPact NW switch disconnector, ENW24272, 1600 A, 4 poles, AC-23A, 690 V, fixed mounting, IP40.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24272 — Identification
ParameterValue
Product typeSwitch disconnector
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24272 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-3
Rated operational current (Ie)AC-23A: 1600 A AC 50/60 Hz 690 V
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-3
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-3
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-3

Breaking & withstand capacity

ENW24272 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)50 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 25 kA during 3 s conforming to IEC 60947-3 at -5...70 °C
Rated short-circuit making capacity (Icm)105 kA AC at 50/60 Hz

Performance

ENW24272 — Performance
ParameterValue
Mechanical durability (cycles)20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3
Electrical durability (cycles)AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3
Utilisation categoryAC-23A

Mechanical & connection

ENW24272 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionRight
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24272 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24272 — Approvals
ParameterValue
StandardsIEC 60947-3

Product details

The ENW24272 is a 1600 A, 4-pole switch disconnector in the EasyPact NW range, rated for AC-23A utilisation at 690 V AC. It is designed for distribution applications where a visible-break isolation point is required — the contact position indicator and IEC 60947-3 suitability-for-isolation marking confirm it serves as a load-break disconnect, not just a switch. Rated short-time withstand current is 50 kA for 1 s (25 kA for 3 s), and the short-circuit making capacity is 105 kA peak at 50/60 Hz — numbers that matter for selectivity studies and upstream breaker coordination. Pollution degree 4 per IEC 60664-1 means it is rated for harsh industrial environments with conductive contamination.

Fixed mounting on a base plate, rear connection, neutral on the right. Dimensions are 537 mm wide × 352 mm high × 297 mm deep — factor those into your enclosure layout. Connection pitch is 115 mm without spreader.

Frequently asked questions

Where can I buy ENW24272 and get pricing?

The ENW24272 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote.

What are the key ratings for ENW24272?

Rated operational current is 1600 A in AC-23A at 690 V AC. Short-time withstand current is 50 kA for 1 s. Short-circuit making capacity is 105 kA peak. Rated insulation voltage is 1000 V, and impulse withstand voltage is 12 kV.

What standards does ENW24272 comply with?

It complies with IEC 60947-3 for switch-disconnectors and IEC 60664-1 for insulation coordination at pollution degree 4. It is suitable for isolation per IEC 60947-3.

MPN
ENW24272