Skip to main content
Schneider Electric ENW33102 — Air Circuit Breakers

Schneider Electric ENW33102 EasyPact NW Rear Connection, 630

MPNENW33102
Active

Schneider Electric EasyPact NW, rear connection, 3 poles, drawout, top mounting, 630...1600 A, ENW33102.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ENW33102 — Identification
ParameterValue
Product typeRear connection
Product rangeEasyPact NW
ENW33102 — Electrical ratings
ParameterValue
Rated current (In)630...1600 A
Poles3P
ENW33102 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Connection pitch70 mm
Connection locationRear
ENW33102 — Other specifications
ParameterValue
Connection positionHorizontal
Localisation on deviceTop
Accessory (separate part category)Connection accessory

Product details

The ENW33102: The 630...1600 A rated current range covers the full EasyPac NW drawout breaker family — from the 630 A frame up to the 1600 A frame. The 70 mm connection pitch is the standard busbar spacing for this class of air circuit breaker, so it aligns with existing switchboard busbar systems. The drawout mounting mode means the breaker chassis stays fixed in the cubicle while the moving portion can be racked out for maintenance or replacement without disturbing the rear power connections.

Integration into the switchboard

This rear connection mounts at the top of the drawout cradle, with horizontal connection orientation. The rear location keeps power cables or busbars out of the front-access zone, which simplifies panel layout and maintains clear separation between the breaker mechanism and the main power terminations. The 70 mm pitch matches standard air circuit breaker busbar centers, so no adaptor plates are needed for most switchboard builds.

Frequently asked questions

What is the rated current range for ENW33102?

The ENW33102 is rated for 630...1600 A, covering the full EasyPact NW drawout breaker family from the 630 A frame through the 1600 A frame.

What mounting mode does ENW33102 use?

ENW33102 uses drawout mounting mode, meaning the breaker chassis stays fixed in the cubicle while the moving portion can be racked out for maintenance.

How do I get current pricing and availability for ENW33102?

ENW33102 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the connection pitch on ENW33102?

The connection pitch is 70 mm, which matches standard air circuit breaker busbar centers for direct integration into switchboards.

MPN