Schneider Electric ENW33114 — Air Circuit Breakers

Schneider Electric ENW33114 EasyPact NW Rear Connection, 3P

MPNENW33114
Active

Schneider Electric EasyPact NW, rear connection, 3 poles, drawout, 630...1250 A, bottom mounting, ENW33114.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ENW33114 — Identification
ParameterValue
Product typeRear connection
Product rangeEasyPact NW
ENW33114 — Electrical ratings
ParameterValue
Rated current (In)630...1250 A
Poles3P
ENW33114 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Connection pitch70 mm
Connection locationRear
ENW33114 — Other specifications
ParameterValue
Connection positionHorizontal Vertical
Localisation on deviceBottom
Accessory (separate part category)Connection accessory

Product details

Rear connection for EasyPact NW drawout breakers

The Schneider Electric ENW33114 is a rear connection accessory for the EasyPact NW range, designed for 3-pole drawout breakers rated 630 to 1250 A. It mounts at the bottom of the breaker and provides horizontal or vertical rear connection positions. Drawout mounting means the breaker chassis slides into a fixed cradle — the rear connection stays in the panel while the breaker unit is withdrawn for maintenance or swap-out without disturbing power wiring. The 70 mm connection pitch matches standard bus-bar spacing for this class of air circuit breaker. This is a connection accessory, not the breaker itself — it provides the fixed rear terminals that mate with the drawout breaker's primary stabs. For a 3-pole system at 630-1250 A, these connections carry full load current and must be torqued to the manufacturer's specification during installation.

Integration notes

The rear connection mounts to the bottom of the EasyPact NW drawout cradle. Connection pitch is 70 mm between phases. Both horizontal and vertical cable entry orientations are supported, giving panel builders flexibility for bus-bar routing or cable ladder drops. Because this is a drawout system, the rear connection stays fixed to the panel — the breaker unit can be racked out for inspection or replacement without disconnecting power cables. Verify the cradle alignment and stab depth before torquing the rear bus connections.

Frequently asked questions

What mounting mode does ENW33114 use?

ENW33114 uses drawout mounting — the rear connection is fixed in the panel cradle, and the breaker unit slides in and out for maintenance.

MPN
ENW33114