Skip to main content
Schneider Electric EVS08H3MF20 — Air Circuit Breakers

Schneider Electric EVS08H3MF20 EasyPact EVS Circuit Breaker,

MPNEVS08H3MF20
Active

Schneider Electric EasyPact EVS, molded case circuit breaker, EVS08H3MF20, 800 A, 65 kA Icu at 440 V AC, 3-pole, electronic trip unit, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS08H3MF20 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS08H3MF20 — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS08H3MF20 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS08H3MF20 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS08H3MF20 — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeFixed
Mounting supportRail Base plate
Contact position indicatorYes
Width422 mm
Height352 mm
Depth297 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS08H3MF20 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS08H3MF20 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS08H3MF20 is a 3-pole EasyPact EVS molded case circuit breaker rated 800 A continuous at 40 °C, with a 65 kA Icu breaking capacity at 440 V AC and 50 kA at 690 V AC per IEC 60947-2. The electronic EVS Trip System2.0 provides LI protection (long-time and instantaneous), with a 20-minute thermal memory that remembers the heat profile before and after a trip, so nuisance reclosing on a still-hot conductor is avoided. Rated insulation voltage is 1000 V AC, and the breaker is certified for isolation per IEC 60947-2 — meaning you can use it as a visible-break disconnect with the contact position indicator confirming the open state.

Fixed-mount design with rear vertical or horizontal connection positions. Mounting support is a rail base plate; connection pitch is 115 mm without a spreader. Dimensions: 422 mm wide, 352 mm high, 297 mm deep — fits standard switchgear cubicle cutouts.

Mechanical durability: 20,000 cycles with maintenance, 10,000 without. Electrical durability for Category B (distribution duty) is 5,000 cycles at 440/690 V without maintenance per IEC 60947-2. Maximum breaking time is 25 ms; maximum closing response time is 70 ms. That 25 ms clearing speed is fast enough to coordinate with downstream breakers in a selective distribution scheme, provided the trip curve settings are properly staged.

Frequently asked questions

What are the key ratings of the EVS08H3MF20?

Rated current 800 A at 40 °C, breaking capacity 65 kA Icu at 440 V AC and 50 kA at 690 V AC, insulation voltage 1000 V AC, 3-pole, electronic LI trip unit.

What compliance certifications does the EVS08H3MF20 carry?

It is listed under UL 508 and CSA C22.2 No. 5, and complies with IEC 60947-2 for CE-marked installations.

Where can I buy the EVS08H3MF20 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
EVS08H3MF20