Skip to main content
Schneider Electric EVS08H3MF20

Schneider Electric EVS08H3MF20 EasyPact EVS Circuit Breaker,

MPN EVS08H3MF20
Active

Schneider Electric EasyPact EVS, molded case circuit breaker, EVS08H3MF20, 800 A, 65 kA Icu at 440 V AC, 3-pole, electronic trip unit, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS08H3MF20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS08H3MF20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS08H3MF20 is a 3-pole EasyPact EVS molded case circuit breaker rated 800 A continuous at 40 °C, with a 65 kA Icu breaking capacity at 440 V AC and 50 kA at 690 V AC per IEC 60947-2. The electronic EVS Trip System2.0 provides LI protection (long-time and instantaneous), with a 20-minute thermal memory that remembers the heat profile before and after a trip, so nuisance reclosing on a still-hot conductor is avoided. Rated insulation voltage is 1000 V AC, and the breaker is certified for isolation per IEC 60947-2 — meaning you can use it as a visible-break disconnect with the contact position indicator confirming the open state.

Fixed-mount design with rear vertical or horizontal connection positions. Mounting support is a rail base plate; connection pitch is 115 mm without a spreader. Dimensions: 422 mm wide, 352 mm high, 297 mm deep — fits standard switchgear cubicle cutouts.

Mechanical durability: 20,000 cycles with maintenance, 10,000 without. Electrical durability for Category B (distribution duty) is 5,000 cycles at 440/690 V without maintenance per IEC 60947-2. Maximum breaking time is 25 ms; maximum closing response time is 70 ms. That 25 ms clearing speed is fast enough to coordinate with downstream breakers in a selective distribution scheme, provided the trip curve settings are properly staged.

MPN
EVS08H3MF20