Schneider Electric EVS08H3MW20 — Air Circuit Breakers

Schneider Electric EVS08H3MW20 EasyPact EVS 800A Circuit Bre

MPNEVS08H3MW20
Active

Schneider Electric EasyPact EVS, circuit breaker, EVS08H3MW20, 800 A, 65 kA Icu at 440 V AC, 3P, drawout, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS08H3MW20 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS08H3MW20 — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS08H3MW20 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS08H3MW20 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS08H3MW20 — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS08H3MW20 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS08H3MW20 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The EVS08H3MW20 is an 800 A drawout circuit breaker from the EasyPact EVS family, built to IEC 60947-2 for distribution duty. The 65 kA Icu at 220–440 V AC is the breaking capacity that governs fault clearance — it safely interrupts a 65 kA prospective short-circuit current without welding or rupturing, which is the figure your coordination study needs for upstream transformer or busbar protection. The EVS Trip System2.0 electronic trip unit provides LI protection — overload (long-time) and instantaneous short-circuit — with a 20-minute thermal memory that remembers prior heating so nuisance trips don't cascade on reclose. That memory window matters for motor feeders where a hot restart could otherwise cause a false trip. Pollution degree 4 per IEC 60664-1 means the breaker is rated for harsh environments — conductive dust or condensation won't cause tracking across the insulation. That's unusual for a distribution breaker and tells you it's built for industrial switchgear, not clean conditioned spaces.

Panel and integration fit

Drawout mounting means the breaker slides into a cradle — no hardwiring the main contacts for removal. That's the standard for switchgear where you need to rack out for maintenance or replacement without de-energizing the bus. The rear connection accepts vertical or horizontal bus orientation, and the 115 mm connection pitch without spreader matches common switchgear bus spacing. The rail base plate is the mounting support; it bolts into the enclosure floor. At 441 mm wide, 439 mm high, and 395 mm deep, the breaker fits standard low-voltage switchgear compartments.

Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. That's typical for a distribution breaker in Category B — it's designed for infrequent switching, not motor-starting duty. The 25 ms maximum breaking time and 70 ms maximum closing time give you the clearing speed for coordination.

Frequently asked questions

How do I get pricing and availability for the EVS08H3MW20?

The EVS08H3MW20 is sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time.

What is the EVS08H3MW20's breaking capacity?

The EVS08H3MW20 has a breaking capacity of 65 kA Icu at 220–440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2.

What compliance standards does the EVS08H3MW20 meet?

The EVS08H3MW20 is designed to IEC 60947-2 and carries pollution degree 4 per IEC 60664-1, with suitability for isolation marking.