Schneider Electric EVS08H3MW5A — Air Circuit Breakers

Schneider Electric EVS08H3MW5A EasyPact EVS Circuit Breaker,

MPNEVS08H3MW5A
Active

Schneider Electric EasyPact EVS, EVS08H3MW5A, 3-pole drawout circuit breaker, 800 A rated current, 65 kA Icu at 440 V AC, electronic EVS Trip System5A trip unit, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS08H3MW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS08H3MW5A — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS08H3MW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS08H3MW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS08H3MW5A — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS08H3MW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS08H3MW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The EVS08H3MW5A is a 3-pole drawout circuit breaker from Schneider Electric's EasyPact EVS range, rated 800 A at 40 °C and built to IEC 60947-2. That 800 A continuous rating means it handles full-load current for distribution feeders or large motor control centers without derating at typical 40 °C ambient — no need to oversize for a warm panel. The 65 kA Icu at 220...440 V AC tells you it can safely interrupt a fault up to that level without blowing apart; at 690 V the interrupting capacity drops to 50 kA, still plenty for most industrial services. The electronic EVS Trip System5A unit gives you overload (long-time), instantaneous short-circuit, and short-time short-circuit protection — adjustable curves for selectivity with downstream breakers. Drawout mounting means you can rack the breaker in and out of the cradle without disturbing the line and load connections — a real time-saver when you're swapping a unit for maintenance or after a fault. The IP40 enclosure protection keeps dust and accidental tool contact out but isn't rated for washdown; mount it in a clean indoor panel, not on a wet floor.

Integration and mounting notes

The drawout cradle mounts to a rail or base plate; rear connections are standard for vertical or horizontal bus. At 441 mm wide by 439 mm high by 395 mm deep, it needs a cutout that fits those dimensions plus clearance for the racking mechanism and arc-chute exhaust. The 115 mm connection pitch without spreader matches standard bus-spacing patterns — no custom bus adapters needed for most switchgear. The 20-minute thermal memory before and after tripping means the trip unit remembers the heat history of the breaker, so a reclose after a near-trip won't let it ride closer to the curve than intended.

Frequently asked questions

What is the breaking capacity of EVS08H3MW5A?

The EVS08H3MW5A has a breaking capacity of 65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2.

What compliance standards does EVS08H3MW5A meet?

The EVS08H3MW5A is designed to IEC 60947-2 and carries a pollution degree 4 rating per IEC 60664-1 for use in harsh environments.

MPN
EVS08H3MW5A