Skip to main content
Schneider Electric EVS08H4MW6A

Schneider Electric EVS08H4MW6A EasyPact EVS Circuit Breaker,

MPN EVS08H4MW6A
Active

Schneider Electric EasyPact EVS EVS08H4MW6A, drawout circuit breaker, 4P, 800 A, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System6A, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS08H4MW6A key specifications
ParameterValue
Control typeManually operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS08H4MW6A additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width556 mm
Height439 mm
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EasyPact EVS08H4MW6A is a 4-pole drawout circuit breaker rated 800 A at 40 °C, with an electronic trip unit (EVS Trip System6A) that covers overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. Its 65 kA Icu at 220...440 V AC (50/60 Hz) per IEC 60947-2 means it can safely interrupt fault currents up to that level without upstream cascading — critical for high-fault-capacity distribution panels. Category B utilisation means it is designed for selectivity with downstream devices, not just cable protection. The drawout mounting and rear connection suit switchgear assemblies where the breaker must be racked out for maintenance without de-energising the bus. The digital display on the trip unit gives local readout of fault type (internal fault, overload, short-circuit, earth fault) and thermal memory status — the 20-minute thermal memory before and after tripping means the breaker remembers its thermal state even after a trip, preventing immediate reclose on a still-hot conductor.

The EVS08H4MW6A is listed as current-production (lifecycle stage: current). No official successor has been assigned — this is the active variant in the EasyPact EVS range.

Mounts on a rail or base plate in a drawout configuration — typical for metal-enclosed low-voltage switchgear (MCC or distribution board). The 556 mm width, 439 mm height, and 395 mm depth define the cell cutout; connection pitch is 115 mm without spreader. Neutral is on the left. Vertical or horizontal connection positions allow top-feed or bottom-feed bus arrangements.

MPN