Schneider Electric EVS12H3MW20

Schneider Electric EVS12H3MW20 EasyPact EVS Circuit Breaker,

MPN EVS12H3MW20
Active

Schneider Electric EasyPact EVS, EVS12H3MW20, drawout circuit breaker, 3-pole, 1250 A, 65 kA at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS12H3MW20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS12H3MW20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS12H3MW20 is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 1250 A at 40 °C with a breaking capacity of 65 kA Icu at 220–440 V AC 50/60 Hz per IEC 60947-2. It uses an electronic EVS Trip System2.0 trip unit with LI protection (long-time overload and instantaneous short-circuit). The drawout mounting means the breaker chassis stays wired to the bus while the moving portion pulls out for maintenance or swap — common in switchgear lineups where downtime needs to be measured in minutes, not hours.

Above that, you derate per the thermal curve. At 690 V AC the Icu drops to 50 kA, still robust for most industrial supplies. The 25 ms maximum breaking time tells you the arc is extinguished within two and a half cycles at 60 Hz — fast enough to limit let-through energy for downstream equipment. That means if a motor starts hot and trips on overload, the breaker remembers the heat and won't reclose immediately — it forces a cooldown period. Useful for motor feeders where repeated hot starts could damage windings.

Drawout mounting on a rail base plate with rear vertical or horizontal connections. The 115 mm connection pitch without spreader matches standard bus-bar spacing in common switchgear cubicles.

MPN
EVS12H3MW20