Schneider Electric EVS16H3MF60 EasyPact EVS Circuit Breaker,

MPNEVS16H3MF60
Active

Schneider Electric EasyPact EVS, EVS16H3MF60, 3-pole circuit breaker, 1600 A, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System6.0, fixed mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS16H3MF60 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS16H3MF60 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS16H3MF60 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS16H3MF60 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS16H3MF60 — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeFixed
Mounting supportRail Base plate
Contact position indicatorYes
Width422 mm
Height352 mm
Depth297 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS16H3MF60 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS16H3MF60 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS16H3MF60 is a 3-pole fixed-mount circuit breaker from the EasyPact EVS range, rated 1600 A at 40 °C and built to IEC 60947-2 for distribution duty. It carries a 65 kA Icu breaking capacity at 220–440 V AC and 50 kA at 690 V AC — that's the maximum fault current it can safely interrupt without damage, which sets the upstream fault level the panel must be rated for.

At 422 mm wide, 352 mm high, and 297 mm deep, this breaker needs a dedicated compartment in the switchboard — it's not a DIN-rail unit. Mounting is fixed to a rail or base plate, with rear vertical or horizontal connection at a 115 mm pitch without spreader. IP40 front face keeps tools and fingers out but doesn't seal against water — keep it indoors or in a weatherproof enclosure.

What the standards tell you

IEC 60947-2 is the standard for low-voltage circuit breakers — it covers the breaking capacity, utilization category, and isolation suitability. This breaker is marked Category B, meaning it's a selective breaker with intentional short-time delay for coordination downstream. Suitability for isolation is certified per the same standard, so it can be used as a visible-break disconnecting means.

Durability and response

Mechanical endurance is 20,000 cycles with maintenance and 10,000 without; electrical endurance is 5,000 cycles at 440/690 V AC without maintenance per IEC 60947-2. Maximum breaking time is 25 ms, and closing response is 70 ms — fast enough to limit let-through energy on a fault. The contact position indicator gives a visual open/closed state, and the fault indication shows internal fault, overload, short-circuit, or earth fault on the trip unit display.

Frequently asked questions

What is the breaking capacity of the EVS16H3MF60?

65 kA Icu at 220–440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. That's the maximum fault current the breaker can safely interrupt at those voltages.

Where can I buy the EVS16H3MF60?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is listed here.

What protection functions does the EVS Trip System6.0 provide?

Overload protection (long time), instantaneous short-circuit protection, short-time short-circuit protection, and earth-fault protection. It also has a 20-minute thermal memory before and after tripping.

What are the mounting dimensions of the EVS16H3MF60?

422 mm wide, 352 mm high, and 297 mm deep. It mounts fixed to a rail or base plate with rear connection at a 115 mm pitch without spreader.