Skip to main content
Schneider Electric EVS16H3MW5A

Schneider Electric EVS16H3MW5A EasyPact EVS Circuit Breaker,

MPN EVS16H3MW5A
Active

Schneider Electric EasyPact EVS, circuit breaker, EVS16H3MW5A, 3P, 1600 A, 65 kA at 440 V AC, drawout, EVS Trip System5A.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS16H3MW5A key specifications
ParameterValue
Control typeManually operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C

All specifications

EVS16H3MW5A additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS16H3MW5A is a 3-pole EasyPact EVS drawout circuit breaker rated 1600 A at 40 °C, built for distribution duty under IEC 60947-2. The 65 kA Icu at 440 V AC (50 kA at 690 V) gives you headroom on fault-clearing — that H breaking-capacity code means it handles high-fault panels without cascading upstream. The EVS Trip System5A electronic trip unit covers overload (long time), short-time, and instantaneous short-circuit protection, with a 20-minute thermal memory before and after tripping so you don't nuisance-trip on a reclose.

Category B utilisation means it's designed for selectivity with downstream breakers — the short-time delay on the Trip System5A lets you coordinate so a feeder fault doesn't take out the main. Drawout mounting means the breaker slides out of its cradle for inspection or swap without disturbing the bus connections — common in switchgear where uptime matters. IP40 keeps fingers and tools out but isn't sealed against dust or water; this lives inside an enclosure, not on the plant floor. Pollution degree 4 per IEC 60664-1 means the internal clearances handle conductive dust or condensation — typical for industrial switchgear, not clean-room panels.

Deployment context

This breaker mounts on a rail or base plate in a switchgear lineup. Connections are rear vertical or horizontal with a 115 mm pitch without spreader — that pitch matters when you're laying out bus bars or cable lugs. The digital display shows fault type (overload, short-circuit, internal fault) so a field tech reads the cause without pulling logs.

MPN
EVS16H3MW5A