Schneider Electric EVS16H3MW5A — Air Circuit Breakers

Schneider Electric EVS16H3MW5A EasyPact EVS Circuit Breaker,

MPNEVS16H3MW5A
Active

Schneider Electric EasyPact EVS, circuit breaker, EVS16H3MW5A, 3P, 1600 A, 65 kA at 440 V AC, drawout, EVS Trip System5A.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS16H3MW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS16H3MW5A — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS16H3MW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS16H3MW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS16H3MW5A — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS16H3MW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS16H3MW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS16H3MW5A is a 3-pole EasyPact EVS drawout circuit breaker rated 1600 A at 40 °C, built for distribution duty under IEC 60947-2. The 65 kA Icu at 440 V AC (50 kA at 690 V) gives you headroom on fault-clearing — that H breaking-capacity code means it handles high-fault panels without cascading upstream. The EVS Trip System5A electronic trip unit covers overload (long time), short-time, and instantaneous short-circuit protection, with a 20-minute thermal memory before and after tripping so you don't nuisance-trip on a reclose.

Category B utilisation means it's designed for selectivity with downstream breakers — the short-time delay on the Trip System5A lets you coordinate so a feeder fault doesn't take out the main. Drawout mounting means the breaker slides out of its cradle for inspection or swap without disturbing the bus connections — common in switchgear where uptime matters. IP40 keeps fingers and tools out but isn't sealed against dust or water; this lives inside an enclosure, not on the plant floor. Pollution degree 4 per IEC 60664-1 means the internal clearances handle conductive dust or condensation — typical for industrial switchgear, not clean-room panels.

Deployment context

This breaker mounts on a rail or base plate in a switchgear lineup. Connections are rear vertical or horizontal with a 115 mm pitch without spreader — that pitch matters when you're laying out bus bars or cable lugs. The digital display shows fault type (overload, short-circuit, internal fault) so a field tech reads the cause without pulling logs.

Frequently asked questions

Where can I buy the EVS16H3MW5A and how is it quoted?

The EVS16H3MW5A is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What does the 65 kA breaking capacity at 440 V mean for my panel?

The 65 kA Icu at 220...440 V AC is the maximum fault current this breaker can safely interrupt once. If your available fault current at the panel is below that, the breaker clears the fault in 25 ms without needing an upstream device to open — that's the H rating's value for high-fault installations.

What protection functions does the EVS Trip System5A provide?

The EVS Trip System5A provides overload (long-time), short-time short-circuit, and instantaneous short-circuit protection. The 20-minute thermal memory means it remembers the heating history before and after a trip, so a quick reclose doesn't cause a nuisance trip on a still-hot breaker.

What are the physical dimensions of the EVS16H3MW5A?

The EVS16H3MW5A has a depth of 395 mm, width of 441 mm, and height of 439 mm. These are the overall dimensions for the drawout breaker; the 115 mm connection pitch without spreader governs bus-bar spacing.

MPN
EVS16H3MW5A