Schneider Electric EVS16H3MW60 — Air Circuit Breakers

Schneider EVS16H3MW60 EasyPact Circuit Breaker, 1600 A, 65 k

MPNEVS16H3MW60
Active

Schneider Electric EasyPact EVS, drawout circuit breaker, EVS16H3MW60, 1600 A, 65 kA Icu at 440 V AC, 3-pole, electronic trip unit EVS Trip System6.0.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS16H3MW60 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS16H3MW60 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS16H3MW60 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS16H3MW60 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS16H3MW60 — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS16H3MW60 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS16H3MW60 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

What this 1600 A drawout breaker does on the line

The Schneider Electric EVS16H3MW60 is a 1600 A drawout circuit breaker from the EasyPact EVS range, built for distribution duty in industrial switchgear. It carries a 65 kA Icu at 220…440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2 — enough to handle high-fault utility feeds without cascading upstream. The electronic EVS Trip System6.0 unit gives you overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection, all adjustable.

Mounting and panel fit — drawout frame, rear connection

Drawout mounting means the breaker slides into a cradle on a rail or base plate — no hard wiring to the breaker body, so swap-out is a racking handle and a few minutes. Rear vertical or horizontal connection at 115 mm pitch without spreader. Dimensions: 441 mm wide, 439 mm tall, 395 mm deep. IP40 on the front, pollution degree 4 per IEC 60664-1 for harsh environments. Contact position indicator is visible through the door.

Durability and duty cycle — Category B, 5000 electrical cycles

Electrical durability: 5000 cycles at 440/690 V AC without maintenance. Mechanical: 20,000 cycles with maintenance, 10,000 without. Maximum breaking time 25 ms, maximum closing time 70 ms. Suitability for isolation is marked yes per the same standard.

Frequently asked questions

What is the breaking capacity of the EVS16H3MW60?

65 kA Icu at 220…440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2.

What protection functions does the EVS Trip System6.0 provide?

Overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection.

Where can I buy the EVS16H3MW60 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider provide for this breaker?

The breaker is designed and tested to IEC 60947-2. Schneider typically provides a Declaration of Conformity and test reports upon request through the supply channel.