Schneider Electric EVS20H3MF20 EasyPact EVS Circuit Breaker,

MPN EVS20H3MF20
Active

Schneider Electric EasyPact EVS, EVS20H3MF20, 3P circuit breaker, 2000 A rated current, 65 kA Icu at 440 V AC, IEC 60947-2, electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS20H3MF20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS20H3MF20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS20H3MF20 is a 3-pole EasyPact EVS circuit breaker rated 2000 A at 40 °C, with a 65 kA Icu breaking capacity at 440 V AC 50/60 Hz per IEC 60947-2. It carries an electronic EVS Trip System2.0 unit providing overload (long-time) and instantaneous short-circuit protection (LI).

If your enclosure runs hotter, expect derating per the manufacturer's thermal curve. Category B utilization (IEC 60947-2) means the breaker is designed for selectivity with downstream devices — it has a deliberate short-time delay capability to let a downstream breaker clear first, keeping supply to healthy circuits. The 20-minute thermal memory before and after tripping means the electronic trip unit remembers the thermal state even after a trip, so re-energizing too quickly won't cause nuisance trips on a still-hot conductor.

Deployment context

The 115 mm connection pitch without spreader matches common busbar drilling patterns for this frame size. Vertical or horizontal connection orientation is permitted, giving flexibility in panel layout.

MPN