Skip to main content
Schneider Electric EVS25H3NF20

Schneider Electric EVS25H3NF20 EasyPact Circuit Breaker, 250

MPN EVS25H3NF20
Active

Schneider Electric EasyPact EVS, EVS25H3NF20, 3P circuit breaker, 2500 A at 40 °C, 65 kA Icu at 440 V AC, electronically controlled, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS25H3NF20 key specifications
ParameterValue
Control typeElectrically operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS25H3NF20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth297 mm
Width422 mm
Height352 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS25H3NF20 is a 3-pole EasyPact EVS circuit breaker rated for 2500 A at 40 °C, with a 65 kA Icu breaking capacity at 220…440 V AC and 50 kA at 690 V AC per IEC 60947-2. It uses an electronic EVS Trip System2.0 trip unit providing overload (long-time) and instantaneous short-circuit protection.

The electronic trip unit allows adjustment of the long-time pickup and delay, plus an instantaneous setting — the 20-minute thermal memory before and after tripping prevents nuisance reclosure on a hot conductor. Category B utilisation means the breaker is intended for distribution with no specific short-time delay requirement, and it carries 5000 electrical cycles without maintenance at 440/690 V. Pollution degree 4 per IEC 60664-1 means the breaker is rated for continuous conductive contamination (e.g., dust with moisture), so it can be placed in industrial panels without sealed enclosures. Suitability for isolation per IEC 60947-2 means the open contacts provide a visible disconnect gap — no separate isolator needed downstream.

Integration notes

Electrically operated — the closing coil draws from the control circuit. Maximum closing response time is 70 ms; maximum breaking time is 25 ms. The contact position indicator is visible on the front of the breaker for local status checks.

MPN