Skip to main content
Schneider Electric EVS32H3MW20

Schneider Electric EVS32H3MW20 EasyPact EVS Circuit Breaker,

MPN EVS32H3MW20
Active

Schneider Electric EasyPact EVS, drawout circuit breaker, EVS32H3MW20, 3200 A, 65 kA Icu at 440 V AC, 3P, electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS32H3MW20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS32H3MW20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The Schneider Electric EVS32H3MW20 is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 3200 A at 40 °C with a 65 kA Icu breaking capacity at 220...440 V AC (50/60 Hz) per IEC 60947-2. At 690 V AC the same unit still delivers 50 kA Icu, so it handles step-down transformer secondary or 690 V distribution without a frame-size jump. The EVS Trip System2.0 electronic trip unit provides LI protection — overload (long-time) and instantaneous short-circuit. Drawout mounting on a rail base plate with rear vertical/horizontal connections gives the panel builder flexibility for cable or busbar entry. The 115 mm connection pitch without spreader keeps phase spacing standard for busbar systems. Mechanical durability is 10,000 cycles without maintenance, 20,000 with — this is a switchgear-class breaker, not a daily-operating contactor, so those numbers suit infrequent switching in distribution.

MPN