Schneider Electric EVS32H3MW5A

Schneider Electric EVS32H3MW5A EasyPact EVS Circuit Breaker,

MPN EVS32H3MW5A
Active

Schneider Electric EasyPact EVS, EVS32H3MW5A, drawout circuit breaker, 3-pole, 3200 A rated current, 65 kA breaking capacity at 440 V AC, electronic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS32H3MW5A key specifications
ParameterValue
Control typeManually operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS32H3MW5A additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The EVS32H3MW5A is a 3200 A drawout air circuit breaker from the Schneider EasyPact EVS family, built for distribution-duty in industrial switchboards. It's a three-pole unit with an electronic EVS Trip System5A trip unit that handles overload, short-time, and instantaneous protection. The 65 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2 means it can interrupt fault currents up to that level without upstream damage — that's the rating that decides whether this breaker holds in a high-fault panel or blows through. At 690 V the breaking capacity drops to 50 kA, still solid for most 690 V distribution. The drawout mounting lets you rack the breaker out for maintenance without pulling bus connections — a real time-saver when you're swapping a trip unit mid-shift.

Drawout mounting on a rail base plate — the breaker chassis slides onto a fixed cradle with rear connection points. The 395 mm depth and 441 mm width give you a solid footprint for a 3200 A frame; make sure your switchgear cubicle has the clearance for the racking mechanism. Vertical or horizontal connection orientation is supported, which helps when you're laying out bus bars in a tight enclosure. The IP40 front-face protection is standard for indoor switchgear — no special sealing needed for a clean panel environment.

Category B utilization means it's designed for selectivity with downstream breakers — the 5000-cycle electrical durability at 440/690 V without maintenance is the endurance figure for that duty. The 25 ms maximum break time is fast enough to limit let-through energy on a hard fault.

Built to IEC 60947-2 for low-voltage switchgear and controlgear. The digital display on the trip unit gives you real-time current readout and fault indication (overload, short-circuit, internal fault), which saves time during commissioning and troubleshooting.

MPN
EVS32H3MW5A