Schneider Electric EVS32H3MW5A — Air Circuit Breakers

Schneider Electric EVS32H3MW5A EasyPact EVS Circuit Breaker,

MPNEVS32H3MW5A
Active

Schneider Electric EasyPact EVS, EVS32H3MW5A, drawout circuit breaker, 3-pole, 3200 A rated current, 65 kA breaking capacity at 440 V AC, electronic trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS32H3MW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS32H3MW5A — Electrical ratings
ParameterValue
Rated current (In)3200 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS32H3MW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS32H3MW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS32H3MW5A — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS32H3MW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS32H3MW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The EVS32H3MW5A is a 3200 A drawout air circuit breaker from the Schneider EasyPact EVS family, built for distribution-duty in industrial switchboards. It's a three-pole unit with an electronic EVS Trip System5A trip unit that handles overload, short-time, and instantaneous protection. The 65 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2 means it can interrupt fault currents up to that level without upstream damage — that's the rating that decides whether this breaker holds in a high-fault panel or blows through. At 690 V the breaking capacity drops to 50 kA, still solid for most 690 V distribution. The drawout mounting lets you rack the breaker out for maintenance without pulling bus connections — a real time-saver when you're swapping a trip unit mid-shift.

Drawout mounting on a rail base plate — the breaker chassis slides onto a fixed cradle with rear connection points. The 395 mm depth and 441 mm width give you a solid footprint for a 3200 A frame; make sure your switchgear cubicle has the clearance for the racking mechanism. Vertical or horizontal connection orientation is supported, which helps when you're laying out bus bars in a tight enclosure. The IP40 front-face protection is standard for indoor switchgear — no special sealing needed for a clean panel environment.

Category B utilization means it's designed for selectivity with downstream breakers — the 5000-cycle electrical durability at 440/690 V without maintenance is the endurance figure for that duty. The 25 ms maximum break time is fast enough to limit let-through energy on a hard fault.

Built to IEC 60947-2 for low-voltage switchgear and controlgear. The digital display on the trip unit gives you real-time current readout and fault indication (overload, short-circuit, internal fault), which saves time during commissioning and troubleshooting.

Frequently asked questions

Where can I buy EVS32H3MW5A and how do I get a price?

This breaker is sourced to order through independent distribution. Submit an RFQ against this order code; availability and current pricing are confirmed at quote time.

What is EVS32H3MW5A's breaking capacity at 440 V?

65 kA Icu at 220...440 V AC 50/60 Hz per IEC 60947-2. At 690 V the rating drops to 50 kA Icu.

What compliance documentation does this brand provide for EVS32H3MW5A?

The breaker is certified to IEC 60947-2 and rated for isolation per that standard. Pollution degree 4 per IEC 60664-1 is confirmed. Standard Schneider documentation includes the datasheet, installation manual, and IEC declaration of conformity.

What is the 20-minute thermal memory on the trip unit?

The EVS Trip System5A retains the thermal state of the breaker for 20 minutes before and after a trip event. This prevents a hot breaker from being re-closed immediately after clearing a fault, reducing the risk of nuisance tripping on a second close.