Schneider Electric EVS40H3MW20 — Air Circuit Breakers

Schneider EasyPact EVS40H3MW20 Circuit Breaker, 4000 A, 65 k

MPNEVS40H3MW20
Active

Schneider Electric EasyPact EVS, circuit breaker, EVS40H3MW20, 3P, 4000 A at 40 °C, 65 kA Icu at 440 V AC, drawout, electronic LI trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS40H3MW20 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS40H3MW20 — Electrical ratings
ParameterValue
Rated current (In)4000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS40H3MW20 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS40H3MW20 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS40H3MW20 — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS40H3MW20 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS40H3MW20 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

What this 4000 A drawout breaker is for

The Schneider Electric EVS40H3MW20 is a 3-pole drawout air circuit breaker from the EasyPact EVS family, rated 4000 A continuous at 40 °C and carrying a 65 kA Icu breaking capacity at 220–440 V AC (50/60 Hz) per IEC 60947-2. The drawout cradle lets you rack the breaker out for maintenance or replacement without disturbing the rear-connected power conductors, which is the standard arrangement for switchgear lineups in industrial distribution.

Trip unit and protection — LI curve, thermal memory, 25 ms clearing

The EVS Trip System2.0 is an electronic LI (long-time + instantaneous) unit. Long-time overload protection follows an I²t curve you can adjust for the load profile; instantaneous short-circuit protection clears in a maximum 25 ms. That 25 ms is the total break time — arcing plus mechanical opening — which is fast enough to limit let-through energy for downstream components. That matters for motor circuits or repeated inrush loads where nuisance tripping on a second start is a real risk.

Mounting and integration — drawout cradle, rear connection, IP40

Mounts in a drawout cradle on a rail base plate; connection pitch is 115 mm without a spreader. Rear connection (vertical or horizontal orientation) mates to the switchgear bus. Pollution degree 4 per IEC 60664-1 means the insulation system is rated for continuous conductive contamination (dust, condensation), which is the typical environment in cement plants, steel mills, and heavy industrial substations.

Durability and duty — Category B, 5000 electrical cycles without maintenance

Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without.

Frequently asked questions

How do I get pricing and availability for the EVS40H3MW20?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution — no public price or stock count is listed.

What is the breaking capacity of the EVS40H3MW20?

65 kA Icu at 220–440 V AC 50/60 Hz, and 50 kA Icu at 690 V AC 50/60 Hz, both per IEC 60947-2.

What trip unit does the EVS40H3MW20 use?

It uses the EVS Trip System2.0 electronic LI unit — long-time overload protection plus instantaneous short-circuit protection, with 20-minute thermal memory.

What compliance documentation is available for the EVS40H3MW20?

The breaker is certified to IEC 60947-2, rated for isolation, and carries pollution degree 4 per IEC 60664-1. Specific RoHS/REACH/UL declarations should be confirmed at quote time — the evidence does not list them individually.