Schneider Electric EVS40H3MW20

Schneider EasyPact EVS40H3MW20 Circuit Breaker, 4000 A, 65 k

MPN EVS40H3MW20
Active

Schneider Electric EasyPact EVS, circuit breaker, EVS40H3MW20, 3P, 4000 A at 40 °C, 65 kA Icu at 440 V AC, drawout, electronic LI trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS40H3MW20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS40H3MW20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

What this 4000 A drawout breaker is for

The Schneider Electric EVS40H3MW20 is a 3-pole drawout air circuit breaker from the EasyPact EVS family, rated 4000 A continuous at 40 °C and carrying a 65 kA Icu breaking capacity at 220–440 V AC (50/60 Hz) per IEC 60947-2. The drawout cradle lets you rack the breaker out for maintenance or replacement without disturbing the rear-connected power conductors, which is the standard arrangement for switchgear lineups in industrial distribution.

Trip unit and protection — LI curve, thermal memory, 25 ms clearing

The EVS Trip System2.0 is an electronic LI (long-time + instantaneous) unit. Long-time overload protection follows an I²t curve you can adjust for the load profile; instantaneous short-circuit protection clears in a maximum 25 ms. That 25 ms is the total break time — arcing plus mechanical opening — which is fast enough to limit let-through energy for downstream components. That matters for motor circuits or repeated inrush loads where nuisance tripping on a second start is a real risk.

Mounting and integration — drawout cradle, rear connection, IP40

Mounts in a drawout cradle on a rail base plate; connection pitch is 115 mm without a spreader. Rear connection (vertical or horizontal orientation) mates to the switchgear bus. Pollution degree 4 per IEC 60664-1 means the insulation system is rated for continuous conductive contamination (dust, condensation), which is the typical environment in cement plants, steel mills, and heavy industrial substations.

Durability and duty — Category B, 5000 electrical cycles without maintenance

Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without.