Schneider Electric EVS40H3MW6A — Air Circuit Breakers

Schneider Electric EVS40H3MW6A EasyPact EVS Circuit Breaker,

MPNEVS40H3MW6A
Active

Schneider Electric EasyPact EVS, EVS40H3MW6A, drawout circuit breaker, 3-pole, 4000 A rated current, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System6A.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS40H3MW6A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS40H3MW6A — Electrical ratings
ParameterValue
Rated current (In)4000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS40H3MW6A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS40H3MW6A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS40H3MW6A — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS40H3MW6A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS40H3MW6A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS40H3MW6A is a 3-pole drawout air circuit breaker from the EasyPact EVS range, rated 4000 A continuous at 40 °C and built to IEC 60947-2 for distribution duty. The 4000 A trip unit rating and 65 kA Icu at 440 V AC mean it handles main-feed or heavy-bus faults without cascading upstream — the H breaking-capacity code tells you it's sized for high-fault installations where a standard breaker would weld shut. The electronic EVS Trip System6A provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection, with a 20-minute thermal-memory reset after a trip so you don't nuisance-trip on a reclose. Drawout mounting means the breaker slides onto a rail or base plate — you can rack it out for maintenance or replacement without disturbing the bus connections. The rear-connected vertical or horizontal terminals accept bus bars or cable lugs at a 115 mm pitch without a spreader.

Category B utilisation means it's designed for selectivity with downstream breakers — the short-time delay lets a fault clear closer to the load before this breaker opens. Mechanical durability of 20,000 cycles with maintenance and 10,000 without tells you it's built for a fixed installation, not frequent switching.

Frequently asked questions

What is the breaking capacity of EVS40H3MW6A?

The EVS40H3MW6A has a breaking capacity of 65 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The H breaking-capacity code indicates high-fault-level capability.

What protection functions does the EVS Trip System6A provide?

The EVS Trip System6A electronic trip unit provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. It includes a 20-minute thermal memory before and after tripping.