EVS40H3NW5A EasyPact EVS 4000A Circuit Breaker, 65kA

MPN EVS40H3NW5A
Active

Schneider Electric EasyPact EVS, EVS40H3NW5A, 4000 A drawout circuit breaker, 3P, 65 kA Icu at 440 V AC, electronic trip unit EVS Trip System5A, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS40H3NW5A key specifications
ParameterValue
Control typeElectrically operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C

All specifications

EVS40H3NW5A additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The EVS40H3NW5A is a 4000 A rated, 3-pole drawout circuit breaker from Schneider Electric's EasyPact EVS range, designed for distribution applications per IEC 60947-2. At 690 V AC the breaking capacity is 50 kA Icu, still substantial for industrial mains. The electronic trip unit (EVS Trip System5A) provides overload protection with long-time delay, short-time short-circuit protection, and instantaneous short-circuit protection. The 20-minute thermal memory before and after tripping means the breaker remembers prior heating events — important for motor or transformer feeders where repeated overloads can accumulate thermal stress. Drawout mounting (with rail and base plate support) allows the breaker to be racked out for maintenance without disturbing the bus connections — standard for large switchgear where downtime for breaker swap must be minutes, not hours. Rear connection, vertical or horizontal orientation, and a 115 mm connection pitch without spreader define the busbar layout.

The part carries IEC 60947-2 certification for circuit-breaker performance, isolation suitability (yes, per standard), and Category B utilization — meaning it is designed for high-fault-level distribution without specific backup protection. Pollution degree 4 per IEC 60664-1 confirms it is rated for harsh industrial environments with conductive pollution.

The digital display provides fault indication for internal fault, overload, and short-circuit events — useful for field service techs to read the last trip cause without external software. The contact position indicator confirms open/closed state mechanically. Electrical durability is rated at 5000 cycles at 440/690 V AC without maintenance per IEC 60947-2. Mechanical durability is 20000 cycles with maintenance, 10000 without. Maximum breaking time is 25 ms — fast enough to limit let-through energy for downstream components.