Schneider Electric EVS40H4NW5A — Air Circuit Breakers

Schneider Electric EVS40H4NW5A EasyPact EVS 4000A Circuit Br

MPNEVS40H4NW5A
Active

Schneider Electric EasyPact EVS, EVS40H4NW5A, 4-pole drawout circuit breaker, 4000 A rated current, 65 kA Icu at 440 V AC, electronic trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS40H4NW5A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS40H4NW5A — Electrical ratings
ParameterValue
Rated current (In)4000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS40H4NW5A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS40H4NW5A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS40H4NW5A — Mechanical & connection
ParameterValue
Control typeElectrically operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS40H4NW5A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS40H4NW5A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS40H4NW5A is a 4-pole drawout air circuit breaker from the EasyPact EVS family, rated 4000 A at 40 °C and built to IEC 60947-2 for distribution duty. That 4000 A continuous rating means it handles the main incoming feed for a large industrial switchboard or a high-current bus riser — not a feeder breaker for a motor control center. The drawout cradle lets you rack the breaker out for maintenance without unbolting power cables, which cuts downtime when you're swapping a trip unit or doing a megger test on the bus.

Rated 65 kA Icu at 220…440 V AC and 50 kA Icu at 690 V AC per IEC 60947-2. The 25 ms maximum breaking time means the arc is quenched inside two cycles at 50 Hz, which limits the let-through energy on downstream gear.

Trip unit and protection logic

Fitted with the EVS Trip System5A electronic trip unit, rated 4000 A. It provides overload (long-time), short-time, and instantaneous short-circuit protection — that's the full curve set you need for selective coordination on a distribution main. The 20-minute thermal memory before and after tripping means the breaker remembers prior heating events, so it doesn't reclose into a still-hot conductor and nuisance-trip again. That matters on a line where a momentary overload from a large motor start could otherwise cause a lockout.

Certified to IEC 60947-2, suitability for isolation marked on the device. Electrical durability: 5000 cycles at 440/690 V without maintenance per Category B. Mechanical durability: 20,000 cycles with maintenance, 10,000 without. That's a solid service life for a main breaker that cycles maybe a few dozen times a year.

Frequently asked questions

Where can I buy EVS40H4NW5A and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send the order code and quantity for a firm price and lead time.

What is the breaking capacity of EVS40H4NW5A?

65 kA Icu at 220…440 V AC and 50 kA Icu at 690 V AC, per IEC 60947-2. That covers most industrial secondary-distribution fault levels without needing an upstream current-limiting device.

What trip unit does EVS40H4NW5A use?

The EVS Trip System5A electronic trip unit, rated 4000 A. It provides long-time overload, short-time, and instantaneous short-circuit protection with a 20-minute thermal memory.