Schneider Electric EZ9F26132

Schneider Electric EZ9F26132 Easy9 MCB, 1P, B Curve, 32 A, 6

MPN EZ9F26132
Obsolete

Schneider Electric Easy9 MCB, EZ9F26132, 1P, B curve, 32 A, 6 kA breaking capacity at 230 V AC, IEC 60898-1, thermal-magnetic, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZ9F26132 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60898-1
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1
Poles1P
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

EZ9F26132 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree2
ColorGrey (RAL 7035)
Depth66.5 mm
Width18 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The EZ9F26132 is a 1-pole miniature circuit breaker from Schneider Electric's Easy9 range, rated 32 A with a B tripping curve. The B curve means the magnetic trip operates at 3 to 5 times In (96–160 A instantaneously), which is the standard choice for resistive and general-purpose loads in residential or light commercial distribution boards — not for motor starting where higher inrush would nuisance-trip a B curve. The 6 kA breaking capacity (Icn and Ics both 6 kA at 230 V AC) tells you it can safely interrupt a fault current up to 6,000 A without welding contacts or cascading damage upstream; that's adequate for most final subcircuits in a TN or TT system where the prospective short-circuit current stays under 6 kA. The 500 V rated insulation voltage (Ui) and 4 kV impulse withstand (Uimp) confirm it's isolated for use in 230/400 V networks per IEC 60898-1.

Deployment context

Clip-on mounting to a 35 mm DIN rail, 18 mm width (1 module), so it slots into a standard distribution board or sub-panel alongside other Easy9 devices. Tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible cable; tightening torque is 3.5 N·m.

MPN
EZ9F26132