Skip to main content
Schneider Electric EZ9F53132

Schneider Electric EZ9F53132 Easy9 MCB, 1P, C-Curve, 32 A, 3

MPN EZ9F53132
Active

Schneider Electric Easy9 series, EZ9F53132, miniature circuit breaker (MCB), 1-pole, C-curve, 32 A rated current, 3 kA breaking capacity at 230 V AC, thermal-magnetic trip, clip-on DIN rail mount, IP20.

$3.30 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZ9F53132 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to SANS 60947-2
Breaking capacity3 kA Icu at 230 V AC 50/60 Hz conforming to SANS 60947-2
Poles1P
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

EZ9F53132 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree2
ColorGrey (RAL 7035)
Depth66.5 mm
Width18 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-5...60 °C

Product details

What it is and what the ratings mean

The Schneider Electric EZ9F53132 is a 1-pole miniature circuit breaker from the Easy9 range, rated 32 A with a C-curve trip characteristic. The C-curve means the magnetic trip operates at 8.5 x In (±20 %), so it handles moderate inrush from motor starters or small transformers without nuisance tripping, while still clearing a hard short fast. The 3 kA breaking capacity (Icu) at 230 V AC is sized for residential and light commercial distribution boards where the prospective fault current stays under that level — typical for a sub-distribution board fed by a larger upstream breaker.

Where it goes and how it mounts

Clip-on mounting on a standard DIN rail (35 mm per EN 60715). At 18 mm wide (1 module pitch), it takes up one slot in a distribution board. The tunnel-type terminals accept up to 35 mm² rigid or flexible copper — enough for the 32 A outgoing circuit. Tightening torque is 3.5 N·m on both line and load sides. IP20 finger-safe terminals are fine inside an enclosed panel; no washdown rating here.

MPN
EZ9F53132