Skip to main content
Schneider Electric EZ9F53363

Schneider Electric EZ9F53363 Easy9 MCB, 63 A, 3P, C-Curve, 3

MPN EZ9F53363
Obsolete

Schneider Electric Easy9 series, EZ9F53363 miniature circuit breaker, 3P, 63 A, C-curve, 3 kA Icu at 400 V AC, thermal-magnetic trip, DIN rail mount.

$11.56 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZ9F53363 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to SANS 60947-2
Breaking capacity3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2
Poles3P
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

EZ9F53363 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree2
ColorGrey (RAL 7035)
Depth66.5 mm
Width54 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The EZ9F53363 is a 63 A, 3-pole miniature circuit breaker from Schneider Electric's Easy9 range, built for distribution boards in residential and light commercial installations. The C-curve (magnetic trip at 8.5 x In ±20%) means it handles moderate inrush from motor-starting or transformer loads without nuisance tripping, while still clearing short-circuit faults fast. Clip-on mounting to DIN rail (35 mm) and tunnel terminals accepting 1–35 mm² rigid or flexible cable make it a straightforward swap into existing distribution boards. The IP20 finger-safe terminals meet the basic touch-protection requirement for enclosed panels.

Coordination and selectivity note

Rated as limitation class 3 per SANS 60947-2, meaning it limits let-through energy enough to allow selective coordination with downstream MCBs in a typical distribution board. The 100% Ics rating (same 3 kA as Icu) means it can be re-closed after clearing a fault at its full rated breaking capacity — no derating for service break duty.

MPN
EZ9F53363