Schneider Electric EasyPact busbar, EZB630W12, 630 A, 12 ways, 40 kA Icw, 690 V insulation voltage.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZB630W12 — Identification
ParameterValue
Product / component typeBusbar
Range of productEasyPact
Product rangeEasyPact
Device applicationConnection
EZB630W12 — Electrical
ParameterValue
Rated current [In]630 A
Rated operational voltage [Ue]550 V AC 50/60 Hz
Rated insulation voltage [Ui]690 V AC 50/60 Hz
EZB630W12 — Mechanical
ParameterValue
Device short namebusbar
Width416 mm
Height590 mm
Depth107 mm
EZB630W12 — Approvals
ParameterValue
StandardsIEC 60439
EZB630W12 — Other specifications
ParameterValue
Number of ways12 ways
Busbar extension2 or 4 ways
Number of devices12 (3P) 18 (2P) 36 (1P)
[Icw] rated short-time withstand current40 kA for 1 s

Product details

The EZB630W12 is a 630 A EasyPact busbar from Schneider Electric, designed for 12-way distribution in panelboards and switchgear assemblies built to IEC 60439. It carries a 40 kA short-time withstand rating for 1 second — that's the fault-clearing capacity the busbar can survive without damage, which governs the upstream breaker coordination and the SCCR of the whole assembly.

This part is officially obsolete per Schneider's lifecycle status. There is no listed direct successor order code. The 630 A rating and 12-way configuration are the critical fit parameters; any substitute must match those to maintain the assembly's short-circuit rating and physical layout.

The 630 A rated current is the continuous thermal rating — it governs the maximum load the busbar can carry without exceeding temperature rise limits in a 40 °C ambient. The 690 V insulation voltage sets the dielectric withstand of the busbar insulation system, while the 550 V operational voltage is the maximum line-to-line voltage at which the busbar is rated to carry that 630 A continuously. The 40 kA Icw for 1 second is the short-time withstand current: the busbar must survive this fault current for one second without mechanical or thermal failure, which is the basis for the short-circuit rating of the entire panel.

Physical configuration and panel fit

At 590 mm high, 416 mm wide, and 107 mm deep, this busbar occupies a substantial footprint in the enclosure. It accommodates 12 three-pole devices, or 18 two-pole, or 36 single-pole breakers — the 12-way count refers to the number of three-pole positions. A busbar extension is available for 2 or 4 additional ways if the layout needs expansion. Mounting and busbar support brackets must be sized for the 630 A continuous current and the 40 kA fault current; verify the enclosure's short-circuit withstand before committing the assembly.

Frequently asked questions

Where can I buy EZB630W12 and how do I get a price?

The EZB630W12 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

What is the closest alternative to EZB630W12?

Schneider has not published a direct successor order code for the EZB630W12. Any replacement must match the 630 A rating, 12-way configuration, and 40 kA short-time withstand to maintain the assembly's short-circuit rating and physical fit.

What compliance standards does EZB630W12 meet?

The EZB630W12 is designed to IEC 60439, the standard for low-voltage switchgear and controlgear assemblies. No RoHS, REACH, UL, or CSA certifications are listed in the available documentation.