Schneider Electric EZC100B3040 — Circuit Breaker Accessories

Schneider EZC100B3040 EasyPact EZC100B, 40 A, 3P, TM-D, 10 k

MPNEZC100B3040
Active

Schneider Electric EasyPact EZC100B, EZC100B3040, 3-pole molded case circuit breaker, 40 A thermal-magnetic TM-D trip unit, 10 kA Icu at 220-240 V AC, IP20, backplate mount.

$41.14Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC100B3040 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100B3040 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]40 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC100B3040 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]0.625 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeB
Trip unit technologyThermal-magnetic
Trip unit rating40 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100B3040 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100B
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm
EZC100B3040 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100B3040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-1 JIS C8201-2-2 GB/T 14048.2

Product details

The Schneider Electric EZC100B3040 is a 3-pole molded case circuit breaker from the EasyPact EZC100B series, fitted with a thermal-magnetic TM-D trip unit rated 40 A at 50 °C. That 40 A rating governs the continuous load it can carry in a distribution panel — sized for a 40 A feeder or branch circuit, not a motor-starting duty. At 440 V AC the breaking capacity drops to 5 kA Icu; at 550 V AC it is 2.5 kA Icu, so verify the available fault current at your service voltage before specifying.

Backplate-mounted, fixed (non-pluggable). The toggle actuator gives positive contact indication (ON/OFF status visible on the breaker face).

Certified to IEC 60947-2 (the main MCCB standard for industrial applications), IEC 60947-1 (general rules), JIS C8201-2-2 (Japanese industrial standard), and GB/T 14048.2 (Chinese national standard). Rated insulation voltage 690 V AC; operational voltage up to 550 V AC. Mechanical durability 13,000 cycles — a standard duty-cycle life for fixed-installation distribution breakers.

Frequently asked questions

Where can I buy the EZC100B3040 and get a price?

The EZC100B3040 is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability; no stock or price figures are published here.

What is the breaking capacity of the EZC100B3040 at different voltages?

The breaking capacity varies with voltage: 10 kA Icu at 110-130 V AC, 10 kA Icu at 220-240 V AC, 7.5 kA Icu at 380 V and 400-415 V AC, 5 kA Icu at 440 V AC, and 2.5 kA Icu at 550 V AC — all per IEC 60947-2. Verify the available fault current at your service voltage against these ratings.

What compliance documentation does the EZC100B3040 carry?

Certified to IEC 60947-2, IEC 60947-1, JIS C8201-2-2, and GB/T 14048.2. Suitable for isolation per IEC 60947-2. Rated pollution degree 3 per IEC 60664-1. The manufacturer provides full IEC compliance documentation with the product.

MPN
EZC100B3040