Skip to main content
Schneider Electric EZC100B3040

Schneider EZC100B3040 EasyPact EZC100B, 40 A, 3P, TM-D, 10 k

MPN EZC100B3040
Active

Schneider Electric EasyPact EZC100B, EZC100B3040, 3-pole molded case circuit breaker, 40 A thermal-magnetic TM-D trip unit, 10 kA Icu at 220-240 V AC, IP20, backplate mount.

$41.14 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100B3040 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100B3040 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width75 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100B3040 is a 3-pole molded case circuit breaker from the EasyPact EZC100B series, fitted with a thermal-magnetic TM-D trip unit rated 40 A at 50 °C. That 40 A rating governs the continuous load it can carry in a distribution panel — sized for a 40 A feeder or branch circuit, not a motor-starting duty. At 440 V AC the breaking capacity drops to 5 kA Icu; at 550 V AC it is 2.5 kA Icu, so verify the available fault current at your service voltage before specifying.

Backplate-mounted, fixed (non-pluggable). The toggle actuator gives positive contact indication (ON/OFF status visible on the breaker face).

Certified to IEC 60947-2 (the main MCCB standard for industrial applications), IEC 60947-1 (general rules), JIS C8201-2-2 (Japanese industrial standard), and GB/T 14048.2 (Chinese national standard). Rated insulation voltage 690 V AC; operational voltage up to 550 V AC. Mechanical durability 13,000 cycles — a standard duty-cycle life for fixed-installation distribution breakers.

MPN
EZC100B3040