Skip to main content
Schneider Electric EZC100F3032 — Circuit Breaker Accessories

Schneider Electric EZC100F3032 EasyPact EZC100F 32A 3P Circu

MPNEZC100F3032
Obsolete

Schneider Electric EasyPact EZC100F, circuit breaker, 3P, 32 A, TM-D trip unit, 25 kA Icu at 240 V AC, IEC 60947-2.

$45.84Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC100F3032 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100F3032 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]32 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC100F3032 — Protection & Performance
ParameterValue
Breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeF
Trip unit technologyThermal-magnetic
Trip unit rating32 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100F3032 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100F
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm
EZC100F3032 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100F3032 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-2 EN/IEC 60947-1 JIS C8201-2-2

Product details

The EZC100F3032 is a 3-pole EasyPact EZC100F circuit breaker from Schneider, rated 32 A at 40 °C (32 A at 50 °C on the trip unit) with a thermal-magnetic TM-D trip unit. The F breaking capacity code tells you it's the high-interrupting version of the EZC100 frame. That means it's fine on 480Y/277 V or 400 V three-phase systems, and the DC rating lets it switch 250 V DC loads (2-pole series) for battery or UPS circuits. The 3t protected poles with no neutral protection mean this is a straight 3-pole breaker — no switched neutral, no 4-pole option on this variant. IP20 finger-safe terminals and IK07 impact resistance (2 J) mean it's protected against accidental contact and light mechanical shock inside a panel. Pollution degree 3 per IEC 60947 handles conductive dust and condensation typical in industrial enclosures. The toggle control gives positive contact indication — you can see and feel the contact position.

Fixed backplate mounting, not DIN rail. The 25 mm pitch matches common busbar and terminal-block layouts. Mechanical durability is 13,000 cycles — that's the expected life under normal switching. For a distribution breaker that sees occasional manual switching and fault clearing, that's plenty. If you're cycling it daily as a disconnect, consider a switch-disconnect instead.

Also carries JIS C8201-2-2 for the Japanese market.

Frequently asked questions

Where can I buy EZC100F3032?

We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is EZC100F3032's breaking capacity at 240 V?

25 kA Icu at 220...240 V AC 50/60 Hz per IEC 60947-2. At 380...415 V it drops to 10 kA, and at 440 V to 7.5 kA. The DC rating is 5 kA at 125 V DC (1P) or 250 V DC (2P).

What standards does EZC100F3032 comply with?

EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It is also suitable for isolation per IEC 60947-2.

What is the closest alternative to EZC100F3032 in the same family?

Within the EasyPact EZC100F frame, the main variant differences are trip rating and pole count. A 3-pole 40 A version (EZC100F3040) shares the same footprint, breaking capacity, and TM-D trip technology — just a higher current setting. No pin-compatible alternative exists outside the EZC100 series.

MPN
EZC100F3032