Skip to main content
Schneider Electric EZC100H1016 — Circuit Breaker Accessories

Schneider Electric EZC100H1016 EasyPact EZC100H, 16 A, 1P, 2

MPNEZC100H1016
Active

Schneider Electric EasyPact EZC100H, circuit breaker, EZC100H1016, 16 A, 1P, 25 kA Icu at 110-130 V AC, thermal-magnetic TM-D trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC100H1016 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100H1016 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]16 A at 40 °C
Rated operational voltage [Ue]125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description1P
EZC100H1016 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 125 V DC conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating16 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100H1016 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width25 mm
Height130 mm
Depth60 mm
EZC100H1016 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100H1016 — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2

Product details

The EZC100H1016 is a 1-pole EasyPact EZC100H circuit breaker with a thermal-magnetic TM-D trip unit rated 16 A at 50 °C. The 25 mm width per pole fits standard 25 mm pitch distribution boards — a single-pole unit occupies one module position. The breaking capacity code H delivers 25 kA Icu at 110-130 V AC and 50 kA Icu at 220-240 V AC, which covers most commercial lighting and small-load branch circuits; at 380-400 V AC it drops to 5 kA, so verify the available fault current at the installation point if feeding a 400 V line. The 10 kA Icu at 125 V DC makes it usable in DC distribution panels up to that voltage, but only for single-pole switching.

Deployment context

IP20 finger-safe terminals allow installation in enclosed panels without additional shrouding.

The toggle control provides positive contact indication — the handle position shows the contact state even if the mechanism is damaged. Mechanical durability is 13,000 cycles, which is standard for a distribution-grade breaker; not rated for frequent switching duty.

Frequently asked questions

How do I get current pricing and availability for EZC100H1016?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — we source through independent distribution channels and quote to order.

What is the breaking capacity of EZC100H1016 at 400 V AC?

At 380-400 V AC the breaking capacity is 5 kA Icu. At 415 V AC it is also 5 kA. For higher fault-current installations, step up to the EZC100H with a higher breaking capacity code.

What compliance documentation does this brand provide for EZC100H1016?

The breaker is certified to EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It carries a rated insulation voltage of 690 V AC and is suitable for isolation per IEC 60947-2. RoHS/REACH declarations are available from Schneider Electric's documentation portal.