Skip to main content
Schneider Electric EZC100H1025

Schneider EasyPact EZC100H1025 MCCB, 25 A, 10 kA

MPN EZC100H1025
Active

Schneider Electric EasyPact EZC100H, 1-pole MCCB, 25 A thermal-magnetic TM-D trip unit, 10 kA Icu at 125 V DC, IP20, backplate mount.

$47.02 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H1025 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100H1025 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width25 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EasyPact EZC100H1025 is a 1-pole molded-case circuit breaker (MCCB) from the EZC100H series, rated 25 A at 50 °C with a thermal-magnetic TM-D trip unit. It breaks up to 10 kA Icu at 125 V DC (1-pole) per IEC 60947-2, and up to 25 kA at 220–240 V AC. The H breaking capacity code means it's sized for commercial and light industrial distribution panels where fault currents stay under 10 kA on DC circuits.

Backplate-mounted with a 25 mm connection pitch — the 25 mm width and 60 mm depth mean it occupies a single 25 mm module slot on a DIN-rail adapter plate. Front-connect terminals allow straight-in wiring from the busbar or cable. IP20 finger-safe housing suits enclosed panel use; IK07 impact rating handles tool drops during commissioning.

Certified to IEC 60947-2 and IEC 60947-1, plus JIS C8201-2-2 and GB/T 14048.2. Rated insulation voltage 690 V AC and operational voltage up to 415 V AC / 125 V DC.

MPN
EZC100H1025